Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* IN COMPLIANCE WITH APPROVED PLANS REAR WALL DETAIL 4 ON SHEET S2 |
|
| 10/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PROVIDED REPORT |
|
| 09/25/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 09/19/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* - GROUTED WITHOUT INSPECTION - HIGH BOND BEAMS, REAR WALL AND 2 SIDE WALLS - ACI GUIDELINES FOR HIGH LIFT GROUT NOT FOLLOWED (CLEANOUTS, ETC) - RETURN TO STRUCTURAL ENGINEER FOR REPAIRS AND RECOMMENDATIONS ON HOW TO PROCEED WITH INSPECTION. PACOMETER, G-BR, X-RAY, ETC. |