Permit: T06CM03151

Parcel: 11202003D

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T06CM03151

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2007 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
TEST OK
CONNECTION OK
VERIFICATION OF GRADE FROM SCHERRER ENGINEER
08/28/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
6" SDR 35 INSTALLED FROM CLEANOUT #8
TO TIE IN AT BLDG, OK TO COVER.
USE SHIELDED COUPLINGS IN LIEU OF FURNCOS
08/24/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
SEWER FROM CLEANOUT #5 TO PLUS OR MINUS EIGHTY FEET PAST CLEANOUT #8 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST.
08/23/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
SEE SECTION 2.2 IAPMO IS 1
PROVIDE FIRM BEDDING
PIPING INSTALLED TO CO #5
08/22/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
PIPING INSTALLED TO CLEANOUT #2
08/21/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
140' REINSTALLED FROM MH
SCHERRER LAND SURVEY ON SITE
04/13/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
PRIVATE SEWER INSTALLATION COMPLETE W/TIE INS AT BUILDING.
TEST OK
NEED VERIFICATION OF GRADE AND CO TERMINATION
VACUUM TEST AT PRIVATE MANHOLE OK
04/12/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
INSTALLED THRU TWO WAY C.O'S
CORRECT HUB AT LAST TIE IN
CORRECT SLOPE AT LAST TIE IN
04/11/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
SEWER INSTALLED FROM MANHOLE TO 1ST BUILDING
DRAIN BRANCH LOCATION. AIR TEST OK.
04/10/2007 PLUMBING - SEWER HCS CONNECT Cancelled
03/30/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
03/30/2007 PLUMBING - SEWER HCS CONNECT Cancelled PETER W/LLOYD 471-8414
03/28/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
PIPING INSTALLED PAST CO #7
03/27/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
4 C O S INSTALLED
PROGRESS OK
03/26/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
1) PROGRESS OK
2) 2 CLEANOUTS PLUS 80' INSTALLED
03/23/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
40' OF PIPING PAST 1ST C O INSTALLED
MANHOLE HAS BEEN SET
VACUUM TEST REQUIRED
03/22/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
6" SEWER INSTALLED TO FIRST CLEANOUT
WILL AIR TEST AT LATER DATE
OK TO CONTINUE
COVER AT OWN RISK, APPROVAL SUBJECT TO PRESSURE TEST
AND VERIFICATION OF GRADE AT C.O INVERTS.
03/21/2007 PLUMBING - SEWER HCS CONNECT Partial Approval TRACER WIRE REQUIRED
1ST PIPE SECTION INSTALLED
OK TO CONTINUE
CALL FOR DAILY PROGRESS INSPECTIONS
03/20/2007 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
MANHOLE BASE OK