Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM03151
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/10/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* - NEED IRR. ASSEM. AND CERT. - NEED BAC T REPORT - NO HOSE THREADS W/OUT VAC BREAKERS - INSTALL AERATORS AT LAUNDRY - HALL SINK IS MISSING CLIPS, IS LEAKING AND HANDLES ARE BACKWARDS - CLAMP ALL DW HOSES 2" BELOW SINK W/PIPE CLAMPS - ADJUST WATER TEMP. INSULATE AT WH - INSTALL STRAINER IN FLOOR SINKS - HAND HELD SHOWER HEADS. - KIT. SINK CO AND PIPE - TRAP PRIMER? CO COVERS |
|
09/25/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK TO COVER KEEP OPEN DRAIN PIPES PLUGGED USE OF WATERLESS URINAL OK PER CASE #070904 ONLY REMAINING ITEM IS THE CONFLICT OF PIPING SPECIFICATIONS. |
|
09/05/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 128, 129 AND 133 TEST OK, REMOVE SHARP METAL TOUCHING VENT |
|
08/17/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UPSTAIRS SHOWER PAN TESTS OK RUN TEST W/HOSE ADA SHOWERS SECURE MECHANICAL CLOSET FLANGES |
|
07/27/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 213-218 DWV TEST OK PIPE INSULATION OK RM 220 DWV AND WATER W/INSULATION OK OK TO COVER WALLS DO NOT COVER CEILING UNTIL HANGERS, VALVE HANDLE EXTENSION AND BRAZING SPECIFICATIONS HAVE BEEN MET |
|
07/25/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 201-204 OK TO COVER AFTER INSULATING RMS 213-218 OK TO INSULATE COPPER DWV NOT UNDER TEST RM 239 INSULATION OK - EXPOSE CW HAMMER ARRESTOR |
|
07/18/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - LETTER RECEIVED ALLOWING SWIVEL LOOP HANGERS FROM KELLY WRIGHT - BREEZEWAY PIPING OK TO COVER - PIPE INSULATION RMS 205-211 OK - PIPE INSULATION TEST ON SHWRS AND CLOSET FLANGES OK IN RMS 221-227 - WATER PIPING IN 239, 236 AND 237 OK TO INSULATE |
|
07/16/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV TEST ON ROOMS 201-211 USE CLEVIS HANGERS PER SPEC 2-8A DOMESTIC WATER PIPING RMS 201-211 OK TO INSULATE |
|
07/06/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV RMS 239, 236, 237 OK SHWR DIVERTORS RMS 224-228 OK TO INSULATE DOMESTIC WATER PIPING IN BREEZEWAY; OK TO INSULATE AFTER PROVIDING CLEARANCE FOR PIPE INSULATION -- NOTE: SPEC #3.9F SPECS OVERSIZED HANGERS TO ALLOW FOR CONTINUOUS INSULATION. ALSO, SEE SPECIFICATION #'S 2-2B, 2-8C AND SEE SPEC 2-7A #2 REQUIRING BRAZED JOINTS ON 2 1/2" AND LARGER COPPER PIPING. |
|
07/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
06/28/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 230, 231, 232, 233, 234 DWV AND COPPER OK EXCEPT FOR SHOWERS AND PIPE INSULATION |
|
06/25/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RMS 132, 138, 139, 140 227, 228, 225, 226, 224, 223, 222 AND 221 OK EXCEPT FOR SHOWER STALLS & CLOSET FLANGES PIPE INSULATION FIRST FLOOR N.E END OK TEST FLOOR LEVEL OFFSET |
|
06/01/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. #105, #106 & EWC AT #109 PVC & N/H TO 2ND FLOOR OK 2. TOILET ROOMS #112 AND BREAKROOM SINK IN #111 OK TO OVERHEAD - OK TO COVER THIS AREA 3. OK TO INSULATE OVERHEAD COPPER 1ST FLOOR |