Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03020

Parcel: 117071400


Addresses:

636 S RAILROAD AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06CM03020

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
01/09/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR/TIGHTEN SCREWS ON VACUUM BREAKERS AT HOSE BIBS
2) COMPLETE WATER HEATER INSTALLATION
3) PTR LINE SHALL BE COPPER OR IRON NOT PVC
4) RAISE DISHWASHER DRAIN HOSE TO BOTTOM OF COUNTER TOP
5) ANTI TIP MISSING AT RANGE
6) ANTI SCALP FAUCETS REQUIRED IN SHOWER
7) CONDENSATION DRAIN SHALL NOT DRAIN IN PLUMBING VENT
8) CAULK TOILET AND TUB AT FLOOR