Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T06CM02811

Parcel: 11922182F


Addresses:

1777 W 36TH ST

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
04/28/2008 ENGINEERING - FINAL Approved Contractro installed handrail.
04/21/2008 ENGINEERING - FINAL Partial Approval Contractor needs to install handrail on new ramp
04/14/2008 ENGINEERING - FINAL Denied Ramp not in compliance with ADA or ANSI.
Ramp is 12%
Side wings are 18%
Approved drawings call for all to be 8% (12 to 1)
03/05/2008 ENGINEERING - FINAL Denied Contractor needs to:
1- Stop dumping material in desert.
2- Install HC parking per approved plans.
3- Install truncated domes per approved plans.