Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02811

Parcel: 11922182F


Addresses:

1777 W 36TH ST

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
04/28/2008 ENGINEERING - FINAL Approved Contractro installed handrail.
04/21/2008 ENGINEERING - FINAL Partial Approval Contractor needs to install handrail on new ramp
04/14/2008 ENGINEERING - FINAL Denied Ramp not in compliance with ADA or ANSI.
Ramp is 12%
Side wings are 18%
Approved drawings call for all to be 8% (12 to 1)
03/05/2008 ENGINEERING - FINAL Denied Contractor needs to:
1- Stop dumping material in desert.
2- Install HC parking per approved plans.
3- Install truncated domes per approved plans.