Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2008 | ENGINEERING - FINAL | Approved | Contractro installed handrail. | |
| 04/21/2008 | ENGINEERING - FINAL | Partial Approval | Contractor needs to install handrail on new ramp | |
| 04/14/2008 | ENGINEERING - FINAL | Denied | Ramp not in compliance with ADA or ANSI. Ramp is 12% Side wings are 18% Approved drawings call for all to be 8% (12 to 1) |
|
| 03/05/2008 | ENGINEERING - FINAL | Denied | Contractor needs to: 1- Stop dumping material in desert. 2- Install HC parking per approved plans. 3- Install truncated domes per approved plans. |