Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM01843
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. REVIEWED GREASE TRAP INSTALLATION STD. WITH PLUMBER |
|
04/07/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) RUNNING TRAP NOT APPROVED 2) MAY NOT REDUCE OUTLET OF FLOW CONTROL 3) N/? BONDS NOT APPROVED FOR ABS 4) INTER MIXING OF NATIONAL TYPES (ABS-PVC) NOT APPROVED 5) PVC "LEG" NOT APPROVED SUPPORT 6) INDIRECT WASTE REQUIRES MINIMUM ONE INCH AIR GAP 7) ABS NOT APPROVED IN EXPOSED EXTERIOR LOCATION 8) VENT TO APPROVED LOCATION 9) OUTLET OF GREASE TRAP MAY NOT BE REDUCED 10) NEED TO SEE CONNECTION TO EXISTING DOWN STREAM OF G.T. 11) WHO INSTALLED NEW WATER LINE OVER HEAD OUTSIDE ? |