Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM01833
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
01/26/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. CONTRACTOR TO DISCONNECT FROM PRIVATE SEWER UNTIL PCDEQ GIVES AUTHORITY TO DISCHARGE. 2. LOCKER ROOMS OK TO COVER 3. AT DRINKING FOUNTAINS: TRAP ARM TO BE SUPPORTED TRAP ARM MAY NOT CHANGE SIZE TRAP AND TRAP ARM TO BE THE SAME SIZE TRAP MAY BE ONLY ONE SIZE LARGER THAN TAILPIECE HORIZ. X HORIZ. CHANGE OF DIRECTION TO BE A SWEEP SUPPORT VERTICAL PIPE |
|
01/24/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* UNCOVER ALL COVERED PIPING FOR INSPECTION. |
|
01/23/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. NOT INSTALLED PER PLAN 2. WATER TEST ON ABS OK PRESSURE TEST OK COPPER OK OK TO INSULATE, HOT WATER PIPING |
|
01/18/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/16/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/12/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/11/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/09/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/08/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* EXPOSE ALTERED W.C AND TEST TRAP ARM FOR EWC TO BE 1 1/2" |