Permit: T06CM01833

Parcel: 10510097A


Addresses:

4240 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM01833

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/30/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
01/26/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. CONTRACTOR TO DISCONNECT FROM PRIVATE SEWER UNTIL PCDEQ GIVES AUTHORITY TO DISCHARGE.
2. LOCKER ROOMS OK TO COVER
3. AT DRINKING FOUNTAINS:
TRAP ARM TO BE SUPPORTED
TRAP ARM MAY NOT CHANGE SIZE
TRAP AND TRAP ARM TO BE THE SAME SIZE
TRAP MAY BE ONLY ONE SIZE LARGER THAN TAILPIECE
HORIZ. X HORIZ. CHANGE OF DIRECTION TO BE A SWEEP
SUPPORT VERTICAL PIPE
01/24/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
UNCOVER ALL COVERED PIPING FOR INSPECTION.
01/23/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. NOT INSTALLED PER PLAN
2. WATER TEST ON ABS OK
PRESSURE TEST OK
COPPER OK
OK TO INSULATE, HOT WATER PIPING
01/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/16/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/12/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/11/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/09/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/08/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
EXPOSE ALTERED W.C AND TEST
TRAP ARM FOR EWC TO BE 1 1/2"