Permit: T06CM01495

Parcel: 10705146A

Inspection Status: Not Applicable

Inspection History: SITE - SEWER

Date Description Inspector Results Comments
11/23/2007 SITE - SEWER Not Applicable IVRS - Inspection :*
08/15/2007 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL A BUSHING ON THIN WALL PIPE TO
MAKE OD SAME AS SCH 40
08/13/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
1. SEWER FOR BLDG #3 INSTALLED OK
WATER TEST FOR SEWER PIPING IS FROM LOWEST POINT TO HIGHEST POINT IN THE SEWER (FLOOR LEVEL)
TEN FOOT HEAD IS FOR BLDG. DRAIN
2. HB2256 REQUIRES A GREEN TRACER WIRE FOR SEWER PIPING