Permit: T06CM00914

Parcel: 14103028A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/26/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/02/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT FROM 2-WAY CLEANOUT THRU BUILDING UNDERGROUND ONLY OK
1. WILL NEED TO SEE PIPE WRAPS PRIOR TO CONCRETE AND TRAP PRIMERS.
2. SHALL REQUIRE WATER TEST THRU ROOF WHEN DRAINAGE FITTINGS ARE INSTALLED ON REVENT PIPING. YOUR REVENT ISOMETRIC IS APPROVED IN ERROR. 2" HORIZONTAL VENT PIPING CANNOT HANDLE THIS # OF FIXTURE UNITS. SEE 2003 UPC FOR CORRECT SIZING ON VENT FOR THIS INSTALLATION.