Permit: T06CM00831

Parcel: 10706023G

Inspection Status: Approved

Inspection History: PLUMBING - PRE SLAB

Date Description Inspector Results Comments
05/01/2007 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
12/04/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
MENS AND WOMENS RESTROOM #109, #110 OK FOR CONCRETE
11/01/2006 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
09/27/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
CELL AREA PRE-SLAB OK
OK FOR CONCRETE
09/12/2006 PLUMBING - PRE SLAB Partial Approval TRENCH DRAIN ON NORTH SIDE READY FOR CONCRETE
07/18/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
1. OK TO CONTINUE INFILLING -- READY FOR CONCRETE.
NOTE: A TRAP AND A TRAP ARM TO BE THE SAME SIZE.
TRAP ARM MAY NOT CHANGE SIZE
TRAP MAY BE ONLY ONE SIZE LARGER THAN THE TAILPIECE.
07/05/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
06/08/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*
1. UNABLE TO LOCATE GENERAL CONTRACTOR'S TRAILER, TO OBTAIN HARD HAT TO GAIN ENTRY.
2. WAITED OUTSIDE NORTH DOORS FOR APPROPRIATE AMT. OF TIME.
3. OK TO POUR NEXT SECTION
RECALL FOR LAST SECTION
06/02/2006 PLUMBING - PRE SLAB Partial Approval IVRS - Inspection :*