Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVE PRIOR TO FLEX WITH TEST ON ENTRIE GAS SYSTEM. PROVIDE APPROVED COUPLINGTS ON GAS PIPING THREAD PROTECTORS ARE NOT APPROVED. PROVIDE HANGERS AT 8' INTERVALS FOR PIPING NO PLUMBERS TAPE. PLEASE CORRECT UNSANITARY CONDITION WITH YOUR PLUMBING WASTE SYSTEM. LEAKS AT SEVERAL LOCATIONS UNDER TRAILER, WASHER TIED IN TO WASTE MAIN, NO TRAP, DRAINAGE FITTING, VENT. PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT APPLIANCES. PROVIDE CORRECT FLUE VENT FOR WATER HEATER. PROVIDE COMBUSTION AIR 100 SQ INCHES 12" FROM CEILING AND 12" FROM FLOOR WITH LOUVERS FOR WATER HEATER. |