Permit: T05PL01466

Parcel: 10603013A


Addresses:

110 E PRINCE RD #11


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05PL01466

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2005 PLUMBING - GAS PRESSURE TEST Approved
09/16/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MINIMUM 10 POUND PRESSURE TEST REQUIRED
2) SECURE GAS LINE AT MATER LOCATION
3) SUPPORT H2O HEATER FLUE SECURELY
4) MOVE COMBUSTIBLE MATERIALS AWAY FROM H2O HEATER
5) CANNOT USE PVC FOR H2O HEATER DRAIN LINE
6) DRAIN LINE MUST TERMINATE TO EXTERIOR OF STOARGE SHED
7) MUST HAVE SHUTOFF VALVE COLD SIDE H2O HEATER
STOPPED INSPECTION