Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) ALL CORRECTIONS HAVE BEEN MADE |
|
| 07/22/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) B-1 VENT PIPE INCORRECT |
|
| 07/20/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE A FULL SIZE 3/4" T & P DRAIN AT WATER HTR 2) SHALL PROVIDE ONE 10 X 10 LOUVER GRILL ON WATER HTR DOOR LOCATED 12" BELOW CEILING 3) SHALL EXTEND WATER HTR FLU VENT AND TERMINATE 3' ABOVE COOLER 4) SHALL REMOVE MECHANICAL TAPE ON DBL WALL FLU VENT AT APPLIANCE COLLAR AT WATER HTR AND PROVIDE (3) SHEET METAL SCREWS PER JOINT 5) OK TO BACKFILL TRENCH 6) GAS PRESSURE TEST IS OK |
|
| 07/15/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT # 271 1) USE LISTED MOBILE HOME FLEX CONNECTOR AT MOBILE HOME. 2) USE PRESSURE GAUGE THAT RENDS 19 1/10 LB INCREMENTS. 3) PROVIDE ACCESS TO FURNACE AND ANY OTHER GAS APPLIANCES. |