Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | FIRE SAFTEY: NO WORKING SMOKE DETECTOR ELECTRICAL: 1) FRONT PORCH LIGHT NOT COMPLETE LACKS GLOBE 2)WEST WALL NORTH RECEP HOT AND NEUTRAL WAS REVERSED, 2ND OUTLET 2-PRONG 3) RECEPS ABOUT THE SINK NOT GFCI PROTECTED 4) LASS SWITCH COVER BROKEN 5) S/E BEDROOM LIGHTS LACKS A GLOBE 6) S/E BEDROOM RECEP EAST WALL SHOWS OPEN GROUND, WEST WALL RECEP SHOWS REVERSED HOT AND NEUTRAL, SOUTH WALL SHOWS, NORTH WALL 2 PRONG 7) LIGHT IN FURNACE ROOM NOT WORKING, NOT COMPLETE, SUB PANEL LACKS A FILLER PLATE-ALSO DOUBLE LUGGED INTERIOR FEATURES 1) FRONT DOOR TRIM AT TOP LACKS PAINT (EXTERIOR) 2) KITCHEN TILE FLOOR DETERIORATING 3) REAR DOOR LACKS WEATHER STRIPPING 1 KNOB ON SCREEN DOOR LOOSE 4) HALL CABINET DOOR FALLING OFF 5) S/E BEDROOM CLOSET DOOR LACKS DOOR PULL, BEDROOM DOOR DETERIORATING STRIKER NEEDS TO BE REPLACED 6) HOLE IN S/E BEDROOM NEEDS REPAIRS 7) S/E BEDROOM WINDOW HAS NOT LOCKING MECHANISM 8) N/E BEDROOM CLOSET DOORS HAVE SERPERATED FROM HINGES 9) BATHROOM DOOR KNOB DOES NOT LOCK 10) HOLE IN HALL WALL NEEDS PATCHING PLUMBING: 1) TOILET LACKS PROPER TOP TO TANK 2) SINK LACKS STOPPER 3) REMOVE LATEX CAULKING FROM TUB PROPERLY SEAL USING SILICONE 4) HOT WATER HEATER HAS NOT DRAIN PAN 5) COLD WATER LINE HAS SHUT OFF BUT RUNS TO BOTTOM OF TANK WITH A HOSE VALVUE (SHUT OFF) FURNACE HEATER NOT WORKING, FUSE BROKE OFF IN OUTLET NEEDS PEST CONTROL |