Case: T05DV01258
Case Details
Entered Date:
12/22/2005
Applicant:
MAHMOOD BASHARAT & NIGHAT JT/RS
Description:
MISC MINIMUM HOUSING.
Outstanding Inspections
Case Number: T05DV01258
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV01258
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2005 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | FIRE SAFTEY: NO WORKING SMOKE DETECTOR ELECTRICAL: 1) FRONT PORCH LIGHT NOT COMPLETE LACKS GLOBE 2)WEST WALL NORTH RECEP HOT AND NEUTRAL WAS REVERSED, 2ND OUTLET 2-PRONG 3) RECEPS ABOUT THE SINK NOT GFCI PROTECTED 4) LASS SWITCH COVER BROKEN 5) S/E BEDROOM LIGHTS LACKS A GLOBE 6) S/E BEDROOM RECEP EAST WALL SHOWS OPEN GROUND, WEST WALL RECEP SHOWS REVERSED HOT AND NEUTRAL, SOUTH WALL SHOWS, NORTH WALL 2 PRONG 7) LIGHT IN FURNACE ROOM NOT WORKING, NOT COMPLETE, SUB PANEL LACKS A FILLER PLATE-ALSO DOUBLE LUGGED INTERIOR FEATURES 1) FRONT DOOR TRIM AT TOP LACKS PAINT (EXTERIOR) 2) KITCHEN TILE FLOOR DETERIORATING 3) REAR DOOR LACKS WEATHER STRIPPING 1 KNOB ON SCREEN DOOR LOOSE 4) HALL CABINET DOOR FALLING OFF 5) S/E BEDROOM CLOSET DOOR LACKS DOOR PULL, BEDROOM DOOR DETERIORATING STRIKER NEEDS TO BE REPLACED 6) HOLE IN S/E BEDROOM NEEDS REPAIRS 7) S/E BEDROOM WINDOW HAS NOT LOCKING MECHANISM 8) N/E BEDROOM CLOSET DOORS HAVE SERPERATED FROM HINGES 9) BATHROOM DOOR KNOB DOES NOT LOCK 10) HOLE IN HALL WALL NEEDS PATCHING PLUMBING: 1) TOILET LACKS PROPER TOP TO TANK 2) SINK LACKS STOPPER 3) REMOVE LATEX CAULKING FROM TUB PROPERLY SEAL USING SILICONE 4) HOT WATER HEATER HAS NOT DRAIN PAN 5) COLD WATER LINE HAS SHUT OFF BUT RUNS TO BOTTOM OF TANK WITH A HOSE VALVUE (SHUT OFF) FURNACE HEATER NOT WORKING, FUSE BROKE OFF IN OUTLET NEEDS PEST CONTROL |
| 08/08/2006 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | CALLED OWNER MAHMOOD BASHARAT, OWNER WAS UPSET THAT THE PERSON INITIATING THE CALL FOR THE TENANT AT #9 WAS NOT SUPPOSED TO BE ON THE THE PREMISES. THE PERSON HAD BEEN EVICTED FROM ONE OF THE UNITS AND WAS HANGING AROUND TENANT IN UNIT #7. FEMALE TENANT IN #9 WAS NOT HOME AT THE TIME OF INSPECTION, ALSO UPSET THAT THE INSEPCTION WAS CONDUCTED WITHOUT HER BEING HOME. SHE ALSO MENTIONED THAT MR. SMITH WHO MADE THE CALL DID NOT LIVE WITH HER, HOWEVER WAS ALSO STOPPING BY HER PLACE FREQUENTLY. * CALLED AND SPOKE WITH RICK SALDATE, EXPLAINED SITUATION; RICK ASKED IF THERE WERE ANY DANGEROUS ISSUES. I EXPLAINED THERE WERE SOME ELECTRICAL ISSUES. RICK ASKED THAT THE OWNER REMOVE THE DBL LUGGING AND REPLACE MISSING COVER PLATES AT THE SAME TIME WORK IS DONE AT #7 AND TO GO AHEAD AND CLOSE CASE. * RETURNED A CALL TO MR. BASHARAT, I EXPLAINED ELECTRAL WOULD NEED TO BE ADDRESSED AT # 9 THE SAME TIME WORK IS DONE AT # 7. BASH AGREED TO DO THE ELECTICAL AT A MINIMUM. F/U IN 30 DAYS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01258
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 02/04/2010 | VIOLATION CLOSED |