Case: T05DV01234

Parcel: 111060090


Addresses:

2919 N ALVERNON WY

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
01/26/2007 INSP - INITIAL CODE ENFORCMENT Approved CASE CLOSED. SUSPENDED. SEE SIRE TO VIEW NOTES/NOV. LM
12/21/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, TOOK PICTURES, MET WITH TENANT AND STARTED INSPECTION. ITEMS FOUND IN UNIT ARE AS LISTED:

FRONT SHOWED SIGNS OF WEATHER STRIPPING DELAPITATED TO THE POINT OF LARGE AMOUNTS OF LIGHT SHOWING THROUGH DOOR STRIKER. LIVING ROOM FOUND TO BE IN GOOD SHAPE. HALL CLOSET WAS FOUND TO HAVE DOORS MISSING. BATHROOM LEAKAGE AROUND BASE OF WATER CLOSET AND WOULDN'T FLUSH PROPERLY. THE OVEN WAS FOUND TO HAVE AN OPERATIONAL STOVE TOP BUT THE OVEN WAS NOT WORKING. FOUND MORTORIZED AIR VENT TO HAVE WATER DAMAGE AND SEPARATED FROM CEILING JOINTS. IN BEDROOM FOUND CLOSET DOORS MISSING, WINDOW AIRCONDITIONING UNIT WAS FOUND TO BE PLUGGED INTO SAME CIRCUIT AS BEDROOM. SWAMP COOLER WAS FOUND TO NOT HAVE BEEN WINTERIZED(IE COOKIE SHEET).

WENT TO EXTERIOR AND FOUND AS LISTED:

FENCE WAS IN A DELAPITATED STATE, LEANING TO THE POINT OF FALLING OVER. THE WATER HEATER CLOSET ROOF WAS DETERIORATED AND LETTING WEATHER ELEMENTS IN. FOUND ON THE ELECTRICAL SUPPLY TO BE IN A DETERIORATED STATE AND SUPPLIED WITH CLOTH BRAIDED THREE WIRE, COMING FROM SERVICE ENTRANCE AND RUNNING THROUGH GABLE ROOFS OF UNITS ONE AND TWO, THEN AT UNIT TWO COMING OUT OF CAR PORT AND GOING DOWN A FOUR BY FOUR SUPPORT POST AND THEN AT BASE GOING UNDERGROUND TO A NON-WEATHER PROOF BOX AT UNIT THREE. TENANT POSED THE QUESTION WOULD THIS HELP HIM GET OUT OF THE LEASE, I TOLD HIM NO. NOTICE OF VIOLATION TO FOLLOW.
12/21/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE TOOK PICTURES, FOUND IN BEDROOM- AIR CONDITIONED PLUGGED IN, BOTH WINDOWS DON'T OPEN. FRONT DOOR SHOW LIGHT BUT NOT SEALED- HEATER HAS A VENT IN THE BACK, INSTALLED ON WALL. CEILING IN KITCHEN IS CRACKED AND SHOWS LEAKAGE. BATHROOM TOILET SHOWS LEAKAGE AT SEAL AT FLOOR AND TOILET DOES NOT FLUSH PROPERLY. CIRCUITS ARE IN GOOD CONDITION.
KITCHEN WINDOW DOES NOT OPEN, BACK DOOR NEEDS ADJUSTMENT. OVEN NEEDS PROPER AGA VALVUE. HALL CLOSET IS MISSING DOORS. HOT WATER HEATER NO ROOFING, DETERIORATED WOOD FENCE LOOSE IN SEVERAL PLACES-COOL COOLER LACKS AZ BOX AND NEEDS WINTERIZED (COOKIE SHEET)
KITCHEN STOVE-OVEN NOT WORKING, NEEDS ADJUSTMENT GABLE AND VENT IS OFF.
ELECTRICAL IS RUN FROM OTHER UNIT AND CROSSED OVER INTO JUNCTION BOX AND FEEDS.