Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING

Entered Date:

12/21/2005

Applicant:

CASAGRANDE THOMAS R & APRIL 40% & BEAN

Description:

MISC MINIMUM HOUSING ISSUES, SEALING, ROOFING AND FENCING.

Outstanding Inspections

Case Number: T05DV01234
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: VOID
Case Number: T05DV01234
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
End Date Description Inspector Results Comments
12/21/2005 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved VISITED SITE TOOK PICTURES, FOUND IN BEDROOM- AIR CONDITIONED PLUGGED IN, BOTH WINDOWS DON'T OPEN. FRONT DOOR SHOW LIGHT BUT NOT SEALED- HEATER HAS A VENT IN THE BACK, INSTALLED ON WALL. CEILING IN KITCHEN IS CRACKED AND SHOWS LEAKAGE. BATHROOM TOILET SHOWS LEAKAGE AT SEAL AT FLOOR AND TOILET DOES NOT FLUSH PROPERLY. CIRCUITS ARE IN GOOD CONDITION. KITCHEN WINDOW DOES NOT OPEN, BACK DOOR NEEDS ADJUSTMENT. OVEN NEEDS PROPER AGA VALVUE. HALL CLOSET IS MISSING DOORS. HOT WATER HEATER NO ROOFING, DETERIORATED WOOD FENCE LOOSE IN SEVERAL PLACES-COOL COOLER LACKS AZ BOX AND NEEDS WINTERIZED (COOKIE SHEET) KITCHEN STOVE-OVEN NOT WORKING, NEEDS ADJUSTMENT GABLE AND VENT IS OFF. ELECTRICAL IS RUN FROM OTHER UNIT AND CROSSED OVER INTO JUNCTION BOX AND FEEDS.
12/21/2005 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved VISITED SITE, TOOK PICTURES, MET WITH TENANT AND STARTED INSPECTION. ITEMS FOUND IN UNIT ARE AS LISTED: FRONT SHOWED SIGNS OF WEATHER STRIPPING DELAPITATED TO THE POINT OF LARGE AMOUNTS OF LIGHT SHOWING THROUGH DOOR STRIKER. LIVING ROOM FOUND TO BE IN GOOD SHAPE. HALL CLOSET WAS FOUND TO HAVE DOORS MISSING. BATHROOM LEAKAGE AROUND BASE OF WATER CLOSET AND WOULDN'T FLUSH PROPERLY. THE OVEN WAS FOUND TO HAVE AN OPERATIONAL STOVE TOP BUT THE OVEN WAS NOT WORKING. FOUND MORTORIZED AIR VENT TO HAVE WATER DAMAGE AND SEPARATED FROM CEILING JOINTS. IN BEDROOM FOUND CLOSET DOORS MISSING, WINDOW AIRCONDITIONING UNIT WAS FOUND TO BE PLUGGED INTO SAME CIRCUIT AS BEDROOM. SWAMP COOLER WAS FOUND TO NOT HAVE BEEN WINTERIZED(IE COOKIE SHEET). WENT TO EXTERIOR AND FOUND AS LISTED: FENCE WAS IN A DELAPITATED STATE, LEANING TO THE POINT OF FALLING OVER. THE WATER HEATER CLOSET ROOF WAS DETERIORATED AND LETTING WEATHER ELEMENTS IN. FOUND ON THE ELECTRICAL SUPPLY TO BE IN A DETERIORATED STATE AND SUPPLIED WITH CLOTH BRAIDED THREE WIRE, COMING FROM SERVICE ENTRANCE AND RUNNING THROUGH GABLE ROOFS OF UNITS ONE AND TWO, THEN AT UNIT TWO COMING OUT OF CAR PORT AND GOING DOWN A FOUR BY FOUR SUPPORT POST AND THEN AT BASE GOING UNDERGROUND TO A NON-WEATHER PROOF BOX AT UNIT THREE. TENANT POSED THE QUESTION WOULD THIS HELP HIM GET OUT OF THE LEASE, I TOLD HIM NO. NOTICE OF VIOLATION TO FOLLOW.
03/13/2006 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved RECEIVED CALL FROM JOHNNY ELECTRIC. OWNER JOHN WAS CONTACTED BY PROPERTY MANAGEMENT CONCERNING ELECTRICAL ISSUES ON NOV ISSUED BY DNR INSPECTORS H LOPEZ AND W NAVARRO. REQUESTED ONSITE MEETING TO REVIEW ELECTRICAL ISSUES NEEDING TO BE ADDRESSED, SET MEETING FOR 2:30 PM ONSITE. CONTACTED W NAVARRO FOR ONSITE MEETING. ARRIVED ONSITE FOR SCHEDULED MEETING TO REVIEW ELECTRICAL ISSUES FORM NOV. PRESENT ON SITE WERE DNR INSPECTORS HLOPEZ, WNAVARRO AND ELECTRICAL CONTACTOR JOHNNY. WALKED SITE AND PRINTED OUT ELECTRICAL VIOLATION AT 2915 MAIN DISCONNECTS, BURRIED ELECTRICAL CONDUCTOR ILLEGALLY FROM UNITS B TO C. DETERIORATED ELECTRICAL 60 AMP DISCONNECTS AND INOPERATIVE GFCI ALONG WITH ADDITIONAL CIRCUITS THAT WHERE DOUBLE LUGGED. ALSO WENT OVER ELECTRICAL ISSUES ON 2925 ILLEGALLY CONVERTED CARPORT WITH ELECTRICAL ISSUES ON 2925 ILLEGALLY CONVERTED CARPORT WITH ELECTRICAL ISSUES. CONTRACTOR AGREED WITH FINDINGS AND WILL HAVE PROPOSAL READY FOR PROPERTY MANAGEMENT WITHIN A WEEK.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01234
Case Status: VOID
Total Completed Case Activity Conditions: 2
Date Name
12/23/2005 NOTICE OF VIOLATION ISSUED
09/26/2006 VIOLATION CLOSED

Documents

File Name Document Type  
IMGP0067ADDRESS.JPG IMAGES VIEW
IMGP0068 FRONT DOOR.JPG IMAGES VIEW
IMGP0069FRONT DOOR.JPG IMAGES VIEW
IMGP0070 HEATER VENT IN BEDROOM.JPG IMAGES VIEW
IMGP0071SMOKE DETECTOR.JPG IMAGES VIEW
IMGP0072AIR CONDITIONER IN BEDROOM.JPG IMAGES VIEW
IMGP0073WINDOW IN BEDROOM .JPG IMAGES VIEW
IMGP0074WINDOW BEDROOM.JPG IMAGES VIEW
IMGP0075 BEDROOM OUTLET.JPG IMAGES VIEW
IMGP0076AIR CONDITIONER IN BEDROOM.JPG IMAGES VIEW
IMGP0077BEDROOM CLOSET.JPG IMAGES VIEW
IMGP0078BEDROOM CLOSET 2.JPG IMAGES VIEW
IMGP0079BEDROOM WINDOW 2.JPG IMAGES VIEW
IMGP0080TOILET.JPG IMAGES VIEW
IMGP0081SHOWER STALL.JPG IMAGES VIEW
IMGP0082SHOWER STALL.JPG IMAGES VIEW
IMGP0083TOILET FLUSHING.JPG IMAGES VIEW
IMGP0084BATHROOM VANITY.JPG IMAGES VIEW
IMGP0085CEILING IN KITCHEN.JPG IMAGES VIEW
IMGP0086BACK DOOR.JPG IMAGES VIEW
IMGP0087HW HEATER ROOF.JPG IMAGES VIEW
IMGP0088BACK FENCE.JPG IMAGES VIEW
IMGP0089NO AZ BOX.JPG IMAGES VIEW
IMGP0090KITCHEN VENT.JPG IMAGES VIEW
IMGP0091RANGE.JPG IMAGES VIEW
IMGP0092HALL CLOSET.JPG IMAGES VIEW
IMGP0093HEATER.JPG IMAGES VIEW
IMGP0094GABLE END.JPG IMAGES VIEW
IMGP0095EXTERIOR AIR CONDITIONER.JPG IMAGES VIEW
IMGP0096J BOX INTO UNIT SUPPLY.JPG IMAGES VIEW
IMGP0097SUPPLY WIRES TO UNIT.JPG IMAGES VIEW
N.O.V. T05DV01234.DOC.LNK DOCUMENTS VIEW
N.O.V. T05DV01234.PDF DOCUMENTS VIEW
NOTES 4-5 6-7 6-22-06.PDF DOCUMENTS VIEW
NOV 11-5-06.PDF DOCUMENTS VIEW
NOV 2-3-06.PDF DOCUMENTS VIEW