Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T05DV01173

Parcel: 130052840


Addresses:

2027 E 34TH ST

Inspection Status: Approved

Inspection History: VANS INITIAL INSP

Date Description Inspector Results Comments
02/09/2006 VANS INITIAL INSP Approved VISITED SITE, UPON ARRIVAL FOUND BLACK TRUCK PARKED INSIDE THE YARD, FROM THE STREET COULD HEAR A GENERATOR RUNNING ISIDE THE STRUCTURE. WALKED INSIDE FOUND A PERSON INSIDE RENNOVATING AND MAKING REPAIRS. EXPLAINED WHO I WAS AND WHY I WAS THERE AND TOLD HIM I WOULD BE TAKING PICTURES. FIRST WALKED THE EXTERIOR OF THE STRUCTURE AND FOUND BOTH UNITS HAD BEEN SECURED, ANY BROKEN WINDOWS HAD BEEN BOARDED AS WELL AS ANY UNSECURES DOORS. DOING MY INITIAL VANS INSPECTION FOUND ROOF HAD BEEN REDONE WITH 3-PLY BUILT UP ROOD, FOUND THE TRIP ROOFING WAS COMPLETED WITH ROOF COATING AND MUCH OF THE FACIA HAD BEEN REPLACED. FOUND PILOS OF ROOFING HAD BEEN REMOVED BUT NEW PILUS AND DEBRIS AND PILES OF USABLE WOOD MATERIALS HAD TAKEN THEIR PLACE (TYPICAL OF A CONSTRUCTION SITE, WATER ALSO HAD BEEN RESTORED)
INSIDE UNIT 2029 I FOUND A LOT OF UNIT HAD BEEN RENNOVATED ALREADY. THE ELECTRICAL FIXTURES HAD BEEN REMOVED ALTHOUGH WIRES HAD BEEN PULLED OUT OF FIXTURES AND EXPOSED, EVERTHING HAD BEEN WIRE-NUTTED. DRYWALL HAD BEEN REPLACED, TAPE AND TEXTURE STARTED. PLUMBING WAS BEING ADDRESSED, LOOK S LIKE LEAKS FOUND AND TILE REMOVED IN THE BATHROOM, KITCHEN PLUMBING AND TILE WERE BEING WORKED ON AS I WAS THERE.
UNIT 2027 REMAINED PRETTY MUCH AS IT HAD BEFORE EXCEPT TRASH AND DEBRIS HAD BEEN REMOCED AND WIRE-NUTTED. I HAVE FOUND A LOT OF PROGRESS IN THE WORK TO THE BUILDING. TRASH AND DEBRIS AROUND THE SITE TYPICAL OF A CONSTRCTION SITE. WILL NEED TO DOUBLE CHECK FOR PERMITS BEING PULLED. PICTURES WERE TAKEN.
12/06/2005 VANS INITIAL INSP Approved VISITED SITE, UPON ARRIVED FOUND PROPERTY IN PLACE BUT PARTICALLY PUSHED OVER. FRONT GATE WAS TIED TOGETHER BY WIRE, BUT FULL OVER WHEN ENTERING. APPOSED STRUCTURE WAS A DISPLAY AT ONE TIME. STRUCTURE TO THE EAST WAS SECURED FROM THE EAST SIDE. STRUCTURE TO THE WEST WAS OPEN AND UNSECURED ( AT FRONT DOOR ) AND EAST SIDE UNIT COULD BE ENTERED FROM THE WEST UNIT. IT OPPOSED THAT RECENT A HUMPTS HAVE BEEN MADE TO RENNORCK THE STRUCTURE, POSSIBLE NEW ROOF-ROOFING MATERIALS PICKED UP IN PILES AROUND THE FRONT YARD. NEW ELECTRICAL SERVICE PARTICALLY INSTELLED. NEW FOSAS HAS BEEN INSTALLED. STRUCTURE WAS ORIGINALLY A DUPLEX CONVERTED TO A SIGNED FAMILY HOME, BEING CONVERTED BACK TO A DUPLEX. HOT WATER HECTER IN WEST UNIT, KITCHEN INSTALLED INCORRECTLY NEW GAS LINES ARE PIPED WRONG. STORE DIRECTLY TO THE RIGHT IS DIRECT WIRRED WITH 220 ELECTRICAL COMING DOWN FROM CEILING CERTAIN ELECTRICAL CIRCUITS WIRRING. TOOLS HAVE BEEN LEFT IN THE INTERIOR OF STRUCTURE. SOME APPLIANCES SETTING IN REAR ROOM. CROOM ENBASED-WORK WITH THAT PERMITS. PICTURES WERE TAKEN.