Case: T05DV01173
Case Details
Entered Date:
12/02/2005
Applicant:
PETERSON PETE B & WEAVER GEORGE JT/RS
Description:
VANS
Outstanding Inspections
Case Number: T05DV01173
Case Status: COMPLIAN
Case Description: VACANT AND NEGLECTED PROGRAM
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV01173
Case Description: VACANT AND NEGLECTED PROGRAM
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2005 | VANS INITIAL INSP | GGOODMAN | Approved | VISITED SITE, UPON ARRIVED FOUND PROPERTY IN PLACE BUT PARTICALLY PUSHED OVER. FRONT GATE WAS TIED TOGETHER BY WIRE, BUT FULL OVER WHEN ENTERING. APPOSED STRUCTURE WAS A DISPLAY AT ONE TIME. STRUCTURE TO THE EAST WAS SECURED FROM THE EAST SIDE. STRUCTURE TO THE WEST WAS OPEN AND UNSECURED ( AT FRONT DOOR ) AND EAST SIDE UNIT COULD BE ENTERED FROM THE WEST UNIT. IT OPPOSED THAT RECENT A HUMPTS HAVE BEEN MADE TO RENNORCK THE STRUCTURE, POSSIBLE NEW ROOF-ROOFING MATERIALS PICKED UP IN PILES AROUND THE FRONT YARD. NEW ELECTRICAL SERVICE PARTICALLY INSTELLED. NEW FOSAS HAS BEEN INSTALLED. STRUCTURE WAS ORIGINALLY A DUPLEX CONVERTED TO A SIGNED FAMILY HOME, BEING CONVERTED BACK TO A DUPLEX. HOT WATER HECTER IN WEST UNIT, KITCHEN INSTALLED INCORRECTLY NEW GAS LINES ARE PIPED WRONG. STORE DIRECTLY TO THE RIGHT IS DIRECT WIRRED WITH 220 ELECTRICAL COMING DOWN FROM CEILING CERTAIN ELECTRICAL CIRCUITS WIRRING. TOOLS HAVE BEEN LEFT IN THE INTERIOR OF STRUCTURE. SOME APPLIANCES SETTING IN REAR ROOM. CROOM ENBASED-WORK WITH THAT PERMITS. PICTURES WERE TAKEN. |
| 05/04/2006 | VANS FOLLOW UP INSP | GGOODMAN | Approved | VISITED SITE, UPON INSPECTION FOUND BOTH UNITS TO HAVE 95% COMPLETED ON THE INTERIOR OF BOTH UNITS. DID FIND PLUMBING, ELECTRICAL, MECHANICAL, DRYWALL & PAINTING COMPLETED WITH MINIMAL TOUCH UP & COMPLETING THE INSTALLATION OF SOME ELECTRICAL & PLUMBING FIXTURES OCCURRING IN BOTH UNITS. CARPET & PADDING WERE READY TO INSTALL WITH THE MATERIALS ON SITE. EXTERIOR OF UNITS WERE HAVING POP WOOD AREAS CUTS INSTALLED AROUND WINDOWS & DOORS HAVE BEEN LATHED IN THE FRONT OF HOUSE READY TO STUCCO & BOTH CARPETS HAVE HAD REPAIRS DONE, WOOD SCRAPED & READY TO PAINT. I WAS INFORMED THAT THE ADDED OR ENCLOSED BACK PORCH WILL BE CONVERTED BACK INTO A PORCH ELIMINATING THE NEED FOR A PERMIT. WILL FOLLOW UP WITH OWNER, PETE PETERSON. AT THE RATE CONSTRUCTION HAS DEVELOPED, I ESTIMATE THE WORK TO BE COMPLETED IN APPROXIMATELY 60 DAYS. |
| 06/28/2006 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | COUNT #7 - PERMITS NOT FINALED. TRP VALVE IN C-PVC NOT APPROVED NEEDS COPPER. COUNT #6 - PORCH REMOVED PERMIT FINALED # T06CM01478 COMBO ROOM TO PORCH COUNT #6 - ELECTRICL PERMIT FINALED # T05EL02380 COUNT #1 - WOP PORCH FOUND TO BE PART OF ORIGINAL STRUCTURE COUNT #2 - ABATED COUNT #3 - ABATED COUNT #4 - ABATED COUNT #5 - ABATED, NEWLY REMODELED |
Completed Activity Special Conditions
Case Description - VACANT AND NEGLECTED PROGRAM
Case Number - T05DV01173
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 01/30/2006 | CONTACTED BY PHONE |
| 12/02/2005 | CONTACTED BY MAILING |
| 01/18/2006 | NOTICE OF VIOLATION ISSUED |
| 01/18/2006 | OLD CASE REFERENCE |
| 04/21/2007 | INFORMATION ONLY |