Case: T05DV01160

Parcel: 121060350


Addresses:

5551 E BELLEVUE ST

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
06/23/2006 INSP - FOLLOW UP CODE ENFORCE Approved MET OWNER AT SITE. REPAIRS HAVE BEEN DONE. WINDOW IS BEING INSTALLED BUT NOT COMPLETED. CARPET IS BEING INSTALLED IN BEDROOMS AND WOOD FLOORING HAS BEEN INSTALLED IN ALL OTHER ROOMS. MET WITH DAVE COX ON PERMIT ISSUES ON WORK WITHOUT PERMIT AND HE WILL BE COMPLETING THE PROCESS. HOUSE IS LACKING BASE BOARDS, TRANSITION STRIPS, AND BEAM WHERE PORCH REMOVED. WILL CHECK IN 10 DAYS.
06/13/2006 INSP - FOLLOW UP CODE ENFORCE Approved STOP BY SITE AND HOUSE IS VACANT, SECURED AND FOR SALE. FOUND A POSINT FOR FORCLOSER POSTED ON GARAGE DOOR. DID CALL OWNER FROM SITE TO GO OVER REPAIRS NEEDED ADVISED OF NOTICE POSTED ON GARAGE DOOR. WE WILL MEET ON FRIDAY TO CHECK REPAIRS DONE. HE IS SUPPOSED TO PICK WINDOW UP TO INSTALL TOMORROW. QUESTIONED PORCH STIL IN BACK YARD AND HE WILL REMOVE TOMORROW. HE IS STATING THAT HE NEVER GOT A COPY OF REPAIRS AND I ADVISED THAT I HAVE BEEN IN CONTACT SEVERAL TIMES AND GAVE HIM A LIST OVER THE PHONE SEVERAL TIMES ON WHAT NEEDED TO BE REPAIRED. WILL MEET IN 3 DAYS.
02/07/2006 INSP - FOLLOW UP CODE ENFORCE Correction Required WENT TO SITE AND NO ONE HOME. CALLED THE OWNER AND IS WORKING ON FINISHING PERMIT PROCESS ON GARAGE. HE IS TRYING TO KEEP THE PORCH IN THE REAR OF STRUCTURE. HE IS WAITING FOR THE WINDOW TO COME IN TO INSTALL IN FRONT BEDROOM. HE THINKS HE WILL HAVE THE PERMIT BY FRIDAY. UNIT IS STILL VACANT AND SECURED. WILL CHECK IN 5 DAYS.
01/27/2006 INSP - FOLLOW UP CODE ENFORCE Correction Required HOUSE IS VACANT AND SECURED. OWNER NOT ON SITE. CALLED OWNER AND LEFT A MESSAGE. OWNER CALLED AND HAD TO LEAVE TOWN DUE TO DEATH IN THE FAMILY. WILL BE BACK NEXT WEEK. WILL CHECK IN 7 DAYS.
12/23/2005 INSP - FOLLOW UP CODE ENFORCE Correction Required WENT TO SITE AND MET THE TENANT. THE SMOKE DETECTORS HAVE BEEN INSTALLED BUT 2 NEED TO BE MOVED TO THE CORRECT HEIGHT DUE TO NOT TO CODE AND NOT TO MANUFACTURE RECOMMENDATION. DID CALL THE OWNER AND HE WILL MOVE THOSE DUE TO A ELECTRICAL CONTRACTOR DID THE SMOKE DETECTORS. NO OTHER WORK HAS BEEN DONE. I DID TELL THE TENANT THAT HE HAS APPLIED FOR THE PERMIT AND WAS DOING THE DRAWINGS. I DID ASK IF THE TENANT WERE MOVING OUT AND THEY SAID YES AND THAT WILL BE AT THE END OF THE MONTH. I WILL CHECK IN 35 DAYS.
12/13/2005 INSP - FOLLOW UP CODE ENFORCE Correction Required MET THE OWNER OF THE PROPERTY AT OFFICE AND WENT OVER THE REPAIRS NEEDED TO BE ADDRESS. DID TELL THE OWNER THAT HE NEEDED TO PUT THE SMOKE DETECTORS BY TODAY AND HE HAS CALLED AN ELECTRICIAN TO INSTALL THOSE BUT CAN'T GET THERE UNTIL AFTER 4:00 PM. I DID TELL THE OWNER THAT WAS OK DUE TO THE TENANT HAS STATED TO ME THAT SHE DOES NOT GET OFF WORK UNTIL AFTER 4:30 PM. WENT TO DSD TO CHECK THE RECORDS AND FOUND WHERE THE BACK ROOM WAS PERMITED BUT WASH ROOM IS LABELED AS A STORAGE ROOM NOT A WASH ROOM. DID GIVE THE COPY'S OF THE PRINTS I GOT FROM DSD RECORDS TO THE OWNER SO HE COULD SHOW WHAT HAS BEEN ADDED. I DID ADVISE THAT A PERMIT FOR THE AC/HEATING UNIT ON ROOF AND WATER HEATER CAN BE GOTTEN AT THE SAME TIME OF THE WASH ROOM INSTEAD AT DIFFERENT TIMES. I DID GO TO THE SITE TO TAKE PICTURES AND THE BOYFRIEND WAS THERE AND HE SHOWED ME WHERE YOU COULD SEE THRU THE ROOF FROM THE BOTTOM. I DID GET ON THE ROOF AND FOUND WHERE IT HAS BEEN PATCHED BEFORE AND YOU COULD SEE THE HOLE WHERE THE LIGHT WAS GOING THRU. THE ROOFING IS LACKING PAINT COVERING ON A 3-PLY ROOF SYSTEM AND HAS SEVERAL PATCHES THRU OUT THE ROOF. I DID FIND AN LB ON THE CONDUIT TO THE AC UNIT WHERE THE COVER PLATE IS LOOSE AND MISSING THE SCREW TO SECURE IT. I DID CALL THE OWNER TO LET HIM KNOW THAT I FOUND THE ROOFING NEEDED TO BE ADDRESS AND THE LB NEEDED TO BE RE-SECURED. THE OWNER CALLED ME TO LET ME KNOW THAT THE ELECTRICIAN WAS ON HIS WAY AND HAS CALLED THE TENANT. THE ELECTRICIAN DID CALL ME TO GO OVER WHAT WAS REQUIRED TODAY AND I ADVISED THE SMOKE DETECTORS AND AN LB ON THE ROOF NEEDED TO BE DONE TODAY. THE OWNER CALLED ME BACK TO LET ME KNOW THAT HE HAS APPLIED FOR THE PERMITS BUT NEEDS SOME DRAWINGS AND WILL START THOSE TOMORROW. HE HAS STATED THAT HE WILL PROBALLY SALE THIS PROPERTY AFTER THE TENANTS MOVE OUT SOON. HE HAD ALREADY HAS BEEN TO THE ASSESSORS OFFICE AND HE WAS TOLD THAT IF HE'S NOT GOING TO BE A RENTAL SOON THAT HE DID NOT HAVE TO REGISTER. HE WILL FAX ME A COPY WHERE THEY SIGNED IT. HAVE NOT RECEIVED FAX YET AND WILL CALL HIM TOMORROW. I DID TELL THE OWNER THAT A SUB PANEL IN A CLOSET IN DINNING ROOM HAS A SHELF IN FRONT OF THE PANEL AND DOES NOT ALLOW ACCESS TO WORK ON THE PANEL AND SHELF HAS BEEN ADDED AND BLOCK THE CORRECT ACCESS FOR CODE ON CLEARANCE. THE DINNING ROOM CLOSET DOOR IS LOOSE AND THIS HAS BEEN TOLD THE OWNER. HE STATED THAT THE ELECTRICIAN WILL REMOVE THE SHELF WHEN HE GOES OVER FOR THE SOMOKE DETECTORS TO BE INSTALLED. WILL CHECK IN 10 DAYS UNLESS CALLED.