Case Details

Status:

COMPLIAN

Type:

RES: VACANT & ABANDONED

Entered Date:

11/29/2005

Applicant:

LANGREHR HEIKO H

Description:

ORIGINALLY REFERRED TO DSD FOR WORK WITHOUT PERMITS ON CARPORT ENCLOSURE. HAS HOLES IN WALLS AND CEILINGS OF CLOSET AND KITCHEN. VARIOUS ELECTRICAL OUTLETS ARE LOOSE IN BATHROOM AND HALL.

Outstanding Inspections

Case Number: T05DV01160
Case Status: COMPLIAN
Case Description: RES: VACANT & ABANDONED
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
12/12/2005 INSP - INITIAL CODE ENFORCMENT RVIDAL Correction Required WENT TO SITE AND MET WITH THE TENANT. SHE LET ME DUE THE INSPECTION. I SAW WHERE THE DOOR FELL OFF TO A STORAGE ROOM. SUPPOSELY IT FELL ON THE DAUGHTER AND KNOCKED HER DOWN. SHE HAS NO CUTS BUT IS BRUISED AND SORE. THE MAIN ELECTRICAL PANEL HAS ADDED CONDUITS TO REAR ADDITION AND A PVC AT LB HAS A SECTION WITH NO PROTECTION OF WIRING AND IS BELOW 8'. FOUND A PORCH ADDED TO SIDE OF ADDITION AT REAR OF HOUSE AND ATTACHMENT IS NOT CORRECT AT DWELLING. HAS RAFTERS TIED TO OVERHANG WITH BOLTS AND NOT BEARING ON WALL. BEAM IS 2-2 X'S AND NOT BEARING ON WALL OR POST. THEY ARE TIED BY NAILS AND BOLT AND HAVE NO METAL ANCHORING SYSTEM. LIVING ROOM HAS CLOSET WITH HOLES IN CEILING AND WALLS, ELECTRICAL OUTLETS HAVE OPEN GROUND AND REVERSED WIRING, FRONT DOOR NOT SEALED PROPERLY. GARAGE HAS A BEAM IN FRONT SECTION THAT HAS BEEN CUT IN MIDDLE SECTION AND EXISTING CARPORT HAS BEEN CONVERTED TO A GARAGE AND NEED TO CHECK FOR PERMITS. KITCHEN HAS OPEN GROUNDS AND HAS BEEN REMOLDED AND LACKING OUTLETS ON COUNTER TOPS, HAS A OPEN END ON A SOFFIT. BATHROOM TUB AND SHOWER DRAINS SLOW, TOILET LACKS BOLTS TO TIED DOWN TOILET TO FLOOR, ELECTRICAL OUTLET NOT GFCI PROTECTED, VANITY HAS NO BACKING ON WALL CAN SEE THE FRAMING. SMOKE DETECTORS ARE LACKING THRU OUT THE DWELLING. NORTH BEDROOM WINDOW MISSING CRANK ON NORTH SIDE, CLOSET DOOR IS MISSING, LIGHT FIXTURE MISSING GLOBE, OPEN GROUNDS ON OUTLETS. HALL HAS A WATER HEATER MISSING TPR VALVE DRAIN LINE AND NO SHUT OFF FOR COLD WATER WHICH APPEARS TO BE INSTALLED WITH OUT A PERMIT, HOLES IN WALLS AND NEED TO CHECK PERMIT FOR NEW AC/HEAT COMBO ON ROOF. MIDDLE ROOM HAS CLOSET LIGHT WITH NO GLOBE AND OPEN GROUNDS ON OUTLETS. SOUTH BEDROOM WINDOW HAS BEEN MADE TO FIX PANEL AND DOES NOT HAVE THE PROPER EGRESS ON THE OTHER WINDOW. SILL IS ABOVE THE 44" AND OPENING OF SLIDER DOES NOT MEET THE REQUIRED OPENING FOR EGRESS OF 5.7 S.F., CLOSET LIGHT FIXTURE MISSING LENSE AND HAS OPEN GROUNDS ON OUTLETS. WATER LINES ARE BACKWARDS ON HOT AND COLD. REAR ROOM OR FAMILY ROOM DOOR TO EXTERIOR NOT SEALED PROPERLY AND NEED TO CHECK FOR PEMITS. WASH ROOM DRYER VENT NOT CONNECTED AND HAS LENT ALL AROUND THE DRYER AND NEEDS TO BE CLEANED. DID TELL THE TENANT THAT SHE SHOULD PROBALLY CLEAN IT HER SELF IF SHE NEEDS TO USE THE DRYER SOON DUE TO THERE IS A LOT OF LENT AND COULD CAUSE A FIRE IF A SPARK TOUCHES IT. SHE SAID SHE WOULD CLEAN IT HERSELF. NO PICTURE TAKEN DUE TO DEAD BATTERYS AND WILL COME BACK AT A LATER TIME. WILL CALL THE OWNER TO GO OVER REPAIRS NEEDED. CALLED AND LEFT A MESSAGE. HE DID CALL ME BACK AT NIGHT AND I GAVE HIM SOME OF THE REPAIRS NEEDED BUT TOLD HIM I DID NOT HAVE THE PACKET. WE WILL MEET AT THE OFFICE TOMORROW TO GO OVER THE ITEMS THAT NEED TO BE ADDRESS. WILL MEET AFTER 9:00 AM AT THE OFFICE AND HE WILL CALL WHEN HE GET CLOSE TO THE OFFICE.

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV01160
Case Description: RES: VACANT & ABANDONED
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/23/2005 INSP - FOLLOW UP CODE ENFORCE RVIDAL Approved WENT TO SITE AND MET THE TENANT. THE SMOKE DETECTORS HAVE BEEN INSTALLED BUT 2 NEED TO BE MOVED TO THE CORRECT HEIGHT DUE TO NOT TO CODE AND NOT TO MANUFACTURE RECOMMENDATION. DID CALL THE OWNER AND HE WILL MOVE THOSE DUE TO A ELECTRICAL CONTRACTOR DID THE SMOKE DETECTORS. NO OTHER WORK HAS BEEN DONE. I DID TELL THE TENANT THAT HE HAS APPLIED FOR THE PERMIT AND WAS DOING THE DRAWINGS. I DID ASK IF THE TENANT WERE MOVING OUT AND THEY SAID YES AND THAT WILL BE AT THE END OF THE MONTH. I WILL CHECK IN 35 DAYS.

Completed Activity Special Conditions

Case Description - RES: VACANT & ABANDONED
Case Number - T05DV01160
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
01/12/2006 CONTACTED BY PHONE
10/30/2006 VIOLATION CLOSED