Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | RECEIVED CALL FROM OWNER. OWNER STATED ALL VIOLATIONS HAVE BEEN ABATED AND REQUESTED COMPLIANCE INSPECTION. SET INSPECTION FOR 6-7-06 APPROXIMETLY 10:00AM. 6-6-06. VISITED SITE ON COMPLIANCE INSPECTION, MADE CONTACT WITH OWNERS WIFE, CONDUCTED COMPLIANCE FW/UP INSPECTION AND FINDING ARE AS FOLLOWS: (5) TC 16-11 E PLUMBING SYS. 2&3 PERMITS REQUIRED 16-4 (4) VIOLATION ABATEl OWNER OCCUPIED STRUCTURES DOES NOT REQUIRE PERMIT FOR INSTALLATION OF TRP DRAIN PIPE. (2) VIOLATION ABATED: KITCHEN CLEAN OUT PLUG INSTALLED (7) TC 16-12 BUILDING AND STRUCTURES EXTERIOR (A) WEATHER PROTECTION 1&2 (4) VIOLATION ABATED - ALL FACSIA AND EXPOSED WOODEN SURFACES HAVE BEEN PAINTED. PICTURES WERE TAKEN. #9 TC 16-4 PERMITS REQUIRED VIOLATION ABATED: ILLEGALLY CONSTRUCTED AND ATTACHED PORCH STRUCTURE ATTACHED TO MAIN STRUCTURE HAS BEEN REMOVED. OWNER HAS COMPLIED. MARK CASE COMPLIANCE. |
|
| 04/17/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE ON FW/UP INSPECTION NO ONE HOME, STRUCTURE HAS BEEN SOLD, ATTEMPTS TO SCHEDULE INSPECTION WITH NEW OWNER HAS NOT BEEN SUCCESSFUL. CALL HAVE BEEN RETURNED TO NEW OWNER & NEW OWNER HAS STATED HE IS READY FOR INSPECTION OF INTERIOR BUT HAS NOT SCHEDULED RE-INSPECTION DATE. N.O.V. WILL BE REISSUED TO NEW OWNER WITH 30 DAY COMPLIANCE TIME FRAME. IF NEW OWNER HAS NOT SET FW/UP INSPECTION WITHIN THE 30 DAY TIME FRAME CITATION WILL BE ISSUED. WILL CHECK RECORDS FOR ELECTRICAL FINAL REQUIRED BY DNR. | |
| 04/03/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE ON FW/UP INSPECTION, PROPERTY HAS BEEN SOLD. ISSUED NEW N.O.V. TO OWNER. PROPERTY IS NO LONGER RENTAL PROPERTY. PROPERTY IS NOW OWNER OCCUPIED. RESULTS OF FW/UP INSPECTION ARE AS FOLLOWS: 1) TC 16-11 BUILDING INTERIORS (A) FIRE SAFETY (B) 1) ABATED - NEW SMOKE DETECTORS INSTALLED IN ALL ROOMS 2) ABATED - ALL WINDOW CRANKS HAVE BEED REPAIRED 2) TC 16-11 HEATING TC16-4 PERMIT REQUIRED. VIOLATION WILL NOT BE ADDRESSED. NO SAFETY ISSUES WERE PRESENT NOR HAZARDOUS INSTALLATION. NO WAY TO DETERMINE WORK WITHOUT PERMIT BY INSTALLATION. GAS PIPING IS ANCHORED PROPERLY. 3) TC 16-11 C1&2 ELECTRICAL SYS. TC 16-4 PERMITS REQUIRED. 1) ABATED - RECEPTACLE SECURED 2) ABATED - GFIC RECEPTACLES INSTALLED IN KITCHEN, BATHROOM & EXTERIOR RECEPTACLES 3) ABATED - HOT NEUTRAL (REVERSED) HAS BEEN CORRECTED, WEATHER PROOF COVER INSTALLED 4) ABATED - VIOLATION ABATED TO CODE REQUIREMENTS UNDER PERMIT #T05EL02131. PERMIT FINALED ON 11-30-05 5) ABATED - VIOLATION ABATED TO CODE REQUIREMENTS UNDER PERMIT #T05EL02131 6) ABATED - VIOLATION REMOVED 4) TC 16-11 BUILDING INTERIORS (D) MECHANICAL EQUIPMENT 1) ABATED - NEW REGISTERS INSTALLED THROUGHOUT STRUCTURE. 2) ABATED - NEW EXHAUST GRILL INSTALLED 3) ABATED - B-VENT HAS BEEN EXTENDED PER CODE REQUIREMENTS 5) TC 16-11 (E) PLUMBING SYSTEM 2 & 3 TC 16-4 PERMITS REQUIRED 1) ABATED - LEAK UNDER SINK REPAIRED 2) ABATED - SHOWER HANDLE & ESCUTCHEON PLATE INSTALLED 3) LEAK REPAIRED 4) NOT ABATED - VIOLATION REMAINS THE SAME, OWNER STATED VIOLATION TO BE ABATED WITHIN TWO WEEKS 5) ABATED - OPENING SEALED & LINES INSULATED - PERMIT NOT REQUIRED. INSTALLATION WAS DONE UNDER COMBO PERMIT WHEN ADDITION WAS COMPLETE. 6) ABATED - SOUTHWEST GAS FOUND NO PROBLEMS ON RECONNECT 12-05. 7) NOT ABATED - SCHEDULED TO BE COMPLETED WITHIN 30 DAYS 8) ABATED - PEDESTAL SINK REMOVED & CABINET STYLE INSTALLED. 6) TC 16-11 (F) INTERIORS FEATURES (2 & 4) 1) ABATED - CEILING & WALLS REPAIRED, AS WELL AS ROOF. 2) ABATED - WALL REPAIRED 3) ABATED - VIOLATION REMOVED 7) TC BUILDING & STRUCTURES EXTERIOR (A) WEATHER PROTECTION 1 & 2 1) WILL NOT BE ADDRESS, OWNER OCCUPIED 2) WILL NOT BE ADDRESS, OWNER OCCUPIED 3) ABATED - NEW WINDOW GLAZING INSTALLED 4) NOT ABATED - OWNER IN PROCESS OF PREPING SURFACES, SHOULD BE COMPLETED WITHIN 30 DAYS. 8) TC 16-12 BUILDING & STRUCTURES EXTERIOR (B) ROOFS ABATED - ROOF SEALED 9) TC 16-4 PERMITS REQUIRED - NOT ABATED AT THIS TIME, OWNER PLANS TO REMOVE VIOLATON & SHOULD BE COMPLETED IN 30 DAYS. NEW OWNER WAS RE-ISSUED ORIGINAL N.O.V. & HAS COMPLETED 90% OF VIOLATIONS. WILL EXTEND ABATEMENT PERIOD FOR 30 DAYS MORE. |
|
| 03/30/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE ON FOLLOW UP INSPECTION. ATTEMPTS TO CONTACT OWNER HAVE FAILED DUE TO NUMBER NO LONGER IN SERVICE. EXTERIOR VIOLATION #7 TC 16-12 BUILDING AND STRUCTURES EXTERIOR (A) WEATHER PROTECTION 1 + 2 1) FRONT DOOR ABATED NEW PRCHANG DOOR INSTALLED, COULD NOT VERIFY BACKDOOR DUE TO NO ONE HOME. 2)FRONT DOOR- ABATE NEW THRESHOLD INSTALLED 3)ABATED-FRONT BROKEN WINDOWS REPLACED 4)NOT ABATED- VIOLATION REMAINS THE SAME #9TC 16-4 PERMITS REQUIRED NOT ABATED- ILLEGALLY ATTACHED PORCH (CARPORT) STILL REMAINS WILL CHECK FOR PERMITS VIOLATION # 1,2,3,4,5,6 & 8 COULD NOT BE ACCESSED DUE TO NO ONE HOME. LEFT RETURN CONTACT FORM REQUESTING CONTACT BY NEW OWNER. STRUCTURE IS NOW OWNER OCCUPIED. |
|
| 08/29/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE, MET WITH TENANT, WALKED UNIT AND FOUND SEVERAL MIN. HOUSING ISSUES AND ARE AS FOLLOWS: FIRE SAFETY- 1. STRUCTURES 1 SMOKE DETECTOR WAS CHECKED AND FOUND NOT TO BE WORKING. ELECTRICAL SYSTEM- 1. RECEPTACLE IN KITCHEN BY STOVE IS NOT SECURED TO WALL 2. GFCI LACKING IN KITCHEN AND BATHROOM 3. TEST EQUIPMENT WAS USED ON INTERIOR RECEPTACLES AND TESTED OUT CORRECTLY. 4. EXTERIOR RECEPTACLE FOR WASHING MACHINE LEACKS WEATHER PROTECTION AND TESTED OUT WITH HOT NATURAL REVERSED. 5. APPEARS NEW ELECTRICAL UP-GRADE DISCONNECT BOX HAS BEEN INSTALLED AND NOT TO CODE, LACKS EQUIPEMENT GROUNDS, IMPROPER INSTALLATION OF CIRCUIT (220) THROUGH BOTTOM OF BOX WITHOUT INSTALLATION IN REQUIRED CONDUIT. ROMEX IS HANGING FROM ELECTRICAL CONDUCTOR CONNECTION INSIDE BOX. IMPROPER COVER FOR PENATRATION ON EASTSIDE OF BOX AND LIDWILL NOT OPEN FULLY DUE TO LONG SELF TAP SCREW THROUGHOUT TOP. 6. J- BOX COOLER NOT SECURED ELECTRICAL CONDUCTOR LACKING PROTECTION THROUGH OPENING AND NOT IN REQUIRED CONDUIT. MECH- 1. REGISTERS MISSING FROM OPENING IN SEVERAL ROOMS 2. KITCHEN EXHAUST FAN NOT WORKING WHEN TESTED. 3. BATHROOM MISSING GRILL FROM EXHAUST VENT 4. B- VENT SYSTEM FOR HOT WATER HEATER DOES NOT EXTEND ABOVE ROOF 3 FT. PLUMBING SYS- 1. KITCHEN SINK PLUMBING LEAKING AND HAS DAMAGED BOTTOM OF CABINET 2. EAST BATHROOM SHOWER LACKING HANDLE AND ESCUCHON PLATE 3. NORTHEAST BATHROOM LACKING SHOWER FAUCET. 4. HOT WATER HEATER LACKS REQUIRED TRP DRAIN 5. HOT AND COLD WATER LINE NOT SECURED TO WALL AND LARGE HOLE APROX. 4X6 IN WALL FOR WATER LINES. 6. CHECK FOR PERMIT FOR WASHING MACHINE 7. CHECK FOR PERMIT GAS PIPING AND NOT SECURED TO WALL AND ON ROOF 8. OSULATE GAS VALVE ON EXTERIOR GAS PIPING 9. OPEN SEWER DRAIN FROM KITCHEN 10. SINK PEDISTAL AND TOILET ARE NOT SECURED PROPERLY. INTERIOR FEATURES- 1. CEILING DAMAGE IN BETWEEN KITCHEN AND DINING ROOM DRYWALL HAS CRUMBLED AWAY EXPOSING HEADER. LEAKS WHEN IT RAINS. TENANT STATED ROOF ABOVE IS BADLY DETERIORATED. 2. LEAKS BEHIND STOVE 3. 1- KITCHEN CABINET BY RANGE NOT SECURED TO WALL 3'' GAP ACCESS CONTROL- 1. SEVERAL BEDROOM WINDOWS CRANKS ARE INOPERABLE AND CAN NOT BE SECURED. 2. REARDOOR LACKING REQUIRED THRESHOLD AND CASING HAS GAP BIG ENOUGH TO SEE OUTSIDE, NOT SEALED PROPERLY. 3. SEVERAL WINDOWS WERE FOUND CRACKED. W/O/P- 1. ADDITION OF CARPORT ATTACHED TO HOUSE FACSIA APPROX 8 FT BY 12 FOOT AND EXTENDS PASS PROPERTY LINE. WAS BUILT IN A HAZARDOUS MANNER, USE OF 2X4 SPANNING MORE THAN 4 FEET. 2. CHECK RECORD FOR ADDITION APPROX 30'X40'. ORIGINALK STRUCTURE MAY HAVE BEEN 1 BEDROOM, LIVING ROOM, KITCHEN W/ DINING ROOM, AND IS EVIDENCED BY OTHER STRUCTURES ON SAME BLOCK. ADDITION CONTAINS FULL BATHROOM, 3 BEDROOMS W/ ELECTRICAL, ROOF TOP FURNACE W/ DUCT WORK. STRUCTURE HAD COOLER ON ROOF AND COOL IS BADLY DETERIORATED 2X4 WERE USED TO SUPPORT COOL ON TOP OF METAL STAND. ELECTRICAL BOX ON ROOF LACKS PROPER WORK CLEARANCES. 2 DETERIORATED COOLERS REMAIN ON ROOF. EXTERIOR FEATURES- 1. LONG TIME WATER LEAK FROM COOLER HAS DETERIORATED METAL. DRIP EDGE AND WOOD ROT HAS SET IN ON FASCIA BOARDS. 2. ROOF OVER HEAD SHOW EVIDENCE OF WOOD ROT, PLYWOOD SHEETING HAS BEGUN TO SPLITER AND SAG 3. PATHC AREA OF FLAT VOOL ROOFING MEETING WITH PITCH ROOF HAS SEVERAL CRACKED AREAS THAT HAVE ALLOWED WATER DAMAGE TO CEILING BETWEEN KITCHEN AND DINING ROOM AND LIVING ROOM. TENANT ARE MOVING OUT AND SHOULD BE OUT BY SEPT 1ST. PICTURES WERE TAKEN. NOV TO FOLLOW COMPLETED RESEARCH. |