Case: T05DV00577
Case Details
Entered Date:
08/12/2005
Applicant:
RASCON JORGE V & EVA G JT/RS
Description:
main cooler not working, major leaking inliving room, sink leaks constantly.
Outstanding Inspections
Case Number: T05DV00577
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 17
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| VIOL(BL) - LIVING AREAS | None | Not Inspected | ||
| VIOL(BL) - ROOF | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL) - CIRCUITS | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| NPO(HC)-COOLING | None | Not Inspected | ||
| NPO(HC)-NO VENTILATION | None | Not Inspected | ||
| NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
| VIOL(SA) - BATHS | None | Not Inspected | ||
| VIOL(SA) - KITCHEN | None | Not Inspected | ||
| NPO - EGRESS | None | Not Inspected | ||
| NPO - SMOKE ALARMS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00577
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2005 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE. INITIAL INSPECTION. ATTEMPTED CONTACT. FOUND NO ONE HOME. LEFT REQUEST FORM FOR RETURN CALL POSTED ON DOOR. TOOK PICTURES OF PROPERTY. EXTERIOR, 2 COOLERS HAVE BEEN LEFT ON ROOF, APPEARS BOTH ARE INOPERATABLE. 1 COOLER ON WESTSIDE ( WINDOW UNIT) IS WORKING. REQUESTED RETURN CALL FOR CONTINUING COMPLAINT. 10 DAY TO RETURN CALL. |
| 08/29/2005 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VISITED SITE, MET WITH TENANT, WALKED UNIT AND FOUND SEVERAL MIN. HOUSING ISSUES AND ARE AS FOLLOWS: FIRE SAFETY- 1. STRUCTURES 1 SMOKE DETECTOR WAS CHECKED AND FOUND NOT TO BE WORKING. ELECTRICAL SYSTEM- 1. RECEPTACLE IN KITCHEN BY STOVE IS NOT SECURED TO WALL 2. GFCI LACKING IN KITCHEN AND BATHROOM 3. TEST EQUIPMENT WAS USED ON INTERIOR RECEPTACLES AND TESTED OUT CORRECTLY. 4. EXTERIOR RECEPTACLE FOR WASHING MACHINE LEACKS WEATHER PROTECTION AND TESTED OUT WITH HOT NATURAL REVERSED. 5. APPEARS NEW ELECTRICAL UP-GRADE DISCONNECT BOX HAS BEEN INSTALLED AND NOT TO CODE, LACKS EQUIPEMENT GROUNDS, IMPROPER INSTALLATION OF CIRCUIT (220) THROUGH BOTTOM OF BOX WITHOUT INSTALLATION IN REQUIRED CONDUIT. ROMEX IS HANGING FROM ELECTRICAL CONDUCTOR CONNECTION INSIDE BOX. IMPROPER COVER FOR PENATRATION ON EASTSIDE OF BOX AND LIDWILL NOT OPEN FULLY DUE TO LONG SELF TAP SCREW THROUGHOUT TOP. 6. J- BOX COOLER NOT SECURED ELECTRICAL CONDUCTOR LACKING PROTECTION THROUGH OPENING AND NOT IN REQUIRED CONDUIT. MECH- 1. REGISTERS MISSING FROM OPENING IN SEVERAL ROOMS 2. KITCHEN EXHAUST FAN NOT WORKING WHEN TESTED. 3. BATHROOM MISSING GRILL FROM EXHAUST VENT 4. B- VENT SYSTEM FOR HOT WATER HEATER DOES NOT EXTEND ABOVE ROOF 3 FT. PLUMBING SYS- 1. KITCHEN SINK PLUMBING LEAKING AND HAS DAMAGED BOTTOM OF CABINET 2. EAST BATHROOM SHOWER LACKING HANDLE AND ESCUCHON PLATE 3. NORTHEAST BATHROOM LACKING SHOWER FAUCET. 4. HOT WATER HEATER LACKS REQUIRED TRP DRAIN 5. HOT AND COLD WATER LINE NOT SECURED TO WALL AND LARGE HOLE APROX. 4X6 IN WALL FOR WATER LINES. 6. CHECK FOR PERMIT FOR WASHING MACHINE 7. CHECK FOR PERMIT GAS PIPING AND NOT SECURED TO WALL AND ON ROOF 8. OSULATE GAS VALVE ON EXTERIOR GAS PIPING 9. OPEN SEWER DRAIN FROM KITCHEN 10. SINK PEDISTAL AND TOILET ARE NOT SECURED PROPERLY. INTERIOR FEATURES- 1. CEILING DAMAGE IN BETWEEN KITCHEN AND DINING ROOM DRYWALL HAS CRUMBLED AWAY EXPOSING HEADER. LEAKS WHEN IT RAINS. TENANT STATED ROOF ABOVE IS BADLY DETERIORATED. 2. LEAKS BEHIND STOVE 3. 1- KITCHEN CABINET BY RANGE NOT SECURED TO WALL 3'' GAP ACCESS CONTROL- 1. SEVERAL BEDROOM WINDOWS CRANKS ARE INOPERABLE AND CAN NOT BE SECURED. 2. REARDOOR LACKING REQUIRED THRESHOLD AND CASING HAS GAP BIG ENOUGH TO SEE OUTSIDE, NOT SEALED PROPERLY. 3. SEVERAL WINDOWS WERE FOUND CRACKED. W/O/P- 1. ADDITION OF CARPORT ATTACHED TO HOUSE FACSIA APPROX 8 FT BY 12 FOOT AND EXTENDS PASS PROPERTY LINE. WAS BUILT IN A HAZARDOUS MANNER, USE OF 2X4 SPANNING MORE THAN 4 FEET. 2. CHECK RECORD FOR ADDITION APPROX 30'X40'. ORIGINALK STRUCTURE MAY HAVE BEEN 1 BEDROOM, LIVING ROOM, KITCHEN W/ DINING ROOM, AND IS EVIDENCED BY OTHER STRUCTURES ON SAME BLOCK. ADDITION CONTAINS FULL BATHROOM, 3 BEDROOMS W/ ELECTRICAL, ROOF TOP FURNACE W/ DUCT WORK. STRUCTURE HAD COOLER ON ROOF AND COOL IS BADLY DETERIORATED 2X4 WERE USED TO SUPPORT COOL ON TOP OF METAL STAND. ELECTRICAL BOX ON ROOF LACKS PROPER WORK CLEARANCES. 2 DETERIORATED COOLERS REMAIN ON ROOF. EXTERIOR FEATURES- 1. LONG TIME WATER LEAK FROM COOLER HAS DETERIORATED METAL. DRIP EDGE AND WOOD ROT HAS SET IN ON FASCIA BOARDS. 2. ROOF OVER HEAD SHOW EVIDENCE OF WOOD ROT, PLYWOOD SHEETING HAS BEGUN TO SPLITER AND SAG 3. PATHC AREA OF FLAT VOOL ROOFING MEETING WITH PITCH ROOF HAS SEVERAL CRACKED AREAS THAT HAVE ALLOWED WATER DAMAGE TO CEILING BETWEEN KITCHEN AND DINING ROOM AND LIVING ROOM. TENANT ARE MOVING OUT AND SHOULD BE OUT BY SEPT 1ST. PICTURES WERE TAKEN. NOV TO FOLLOW COMPLETED RESEARCH. |
| 01/18/2006 | EMERGENCY CALL OUT | HLOPEZ | Approved | DID OFU NO CONTACT WITH BY OWNER HAS BEEN MADE. OFFICE RECIEVED CERT MAIL ON 11-16-05. CONTACTED OWNER TO REQQUEST STATUS OF ABATED NOV. HE STATED YES, HE HAD ALLOWED LOWER BID TO BE ACCEPTED. INFORMED OWNER HE SHOULD OF MADE CONTACT WITH DNR, NEW OWNER DOES NT AGREE TO ABATE ISSUES HE COULD BE HELD RESPONSIBLE FO ABATEMENT OF ISSUES. ATTEMPTED CONTACTING NEW OWNER NO ONE ANSWER, LEFT MESSAGE. NHENRY |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00577
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 11/03/2005 | NOTICE OF VIOLATION ISSUED |
| 06/09/2006 | VIOLATION CLOSED |