Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | 09-26-2005 CALLED PHONE NUMBER ON COMPLAINT FORM,LINE BUSY,VISITED SITE,NO ONE HOME,LEFT NO ONE HOME LETTER IN DOOR,FIVE DAYS TO RESPOND,DID NOTICE CARPORT ROOF APPEARS TO BE ADDED ,WATER LINES ALTERED,GAS LINES ALTERED,TOOK PICTURES. RESIDENT CAME HOME.THERE IS A SIXTY AMPERE SERVICE ENTRANCE THAT IS DOUBLE LUGGED,HAS NEW SERVICE FOR AIR CONDITIONER. TENANTS STATED THAT OWNER HAD SHUT WATER OFF TWO WEEKS AGO.TENANTS TURNED BACK ON. FENCE IS IN DELAPADATION.ELECTRICAL,TWELVE TWO ROMEX IS RUN FROM JUNCTION BOX TWO CEILING FANS(TWO)OUTLETS THREE PRONG POSSIBLE TWO WIRE SERVICE.LAUNDRY ROOM WORK WITHOUT PERMITS,WASHER AND DRYER HOOKED UP ILLEGAL-P-TRAP WRONG CONNECTIONS,NEW COPPER LINES,EXPOSED ROMEX,P.R. VALVE HOOKED INTO P. TRAP,GAS FLEX THRU THE WALL,TWO CONNECTORS TIED TOGETHER. CEILING HEIGHT AT SIX FOOT WALLS,GROUT IN TILE COMMING OUT.SMOKE DETECTORS DO NOT WORK,AIR GAP ON FRONT DOOR. ELECTRIC UNDER SINK FOR DISHWASHER IS INSTALLED INCORRECTLY. |