Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

03/02/2005

Applicant:

HAAG ALBERT J & GINA R

Description:

COMPLAINT:MIN HOUSING- LEAKY ROOF, WHEN IT RAINS, DAMAGED TILE.

Outstanding Inspections

Case Number: T05DV00164
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 27
End Date Description Inspector Results Comments
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - ATTACHED STRUCTURES None Not Inspected
VIOL(BL) - FOUNDATION None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
VIOL(BL) - ROOF None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
VIOL(EL) - OTHER None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
NPO(HC)-COOLING None Not Inspected
NPO(HC)-NO VENTILATION None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
VIOL(HC) - OTHER None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - INSECTS/PESTS None Not Inspected
VIOL(PC) - RODENTS None Not Inspected
NPO - EGRESS None Not Inspected
09/26/2005 NPO - SMOKE ALARMS JHURD Correction Required 9/26/05, VISITED SITE, TOOK PICTURES, CALLED NUMBER ON COMPLAINT FORM LINE BUSY, VISITED SITE, NO ONE HOME, LEFT NO ONE HOME LETTER IN DOOR 5 DAYS TO RESPOND, WHILE DOING THIS NOTICED A GAS LINE HAD BEEN INSTALLED IN CARPORT AREA, WATER LINES ALTERED INSTALLED AT FRONT OF HOUSE, CARPORT COVERING LOOKS AS IF BEEN ADDED, LACKS CLIPS, TIES, TIE DOWNS, BASE CAPS, CARPORT EDGE ON EAST SIDE 6', WHILE DOING NOTES IN VEHICLE, OCCUPANTS SHOWED UP, DONE INSP. FOUND DOUBLE LUGGING ON 60 AMP SERVICE, DISCONNECT SIDE, DOUBLE LUGGING ON GROUNDING. WOOD SLATTED FENCE DETERIORATED, ROTTEN, BUSTED SUPPORTS, AND SLATS, LAUNDRY ROOM ADDED CEILING APPOX. 6' ELECTRICAL INSTALLED, ALSO ELECT. ADDED CIRCUITS FOR WASHER /DRYER, EXPOSED ROMEX IN HOT WATER ROOM TO SUPPLY ELECT. WRONG DRAIN LINE CONNECTIONS, HOT WATER PRV DRAIN LINE GOES INTO P-TRAP AND THEN INTO SEWER VENT LINE,FLUE PIPE NOT PROPERLY SEALED, EXPOSED ELECTRIC IN JUNCTION BOX, ADDED WATER LINES, UNDER KITCHEN SINK ALTERED WATER LINES, ADDED ROMEX FOR ELECT. 4-GANG OUTLET BOX INSTALLED, 3-PRONG CONVENIENCE OUTLETS INSTALLED ON 2-WIRE SYSTEM, 1 BROKEN CONVENIENCE OUTLET, FRONT DOOR LACKS WEATHER PROTECTION, CEILING FAN INSTALLED WITH ADDED ELECTRIC CIRCUIT. WATER LINES ADDED RUNS DIRECTLY NEXT TO SUB-PANEL, DOOR WILL NOT OPEN PROPERLY, ADDED LIGHT FIXTURE WITH ADDED ELECT. TUB DIVERTER CONTINOUSLY LEAKS. GROUT AND CAULKING SPLIT DETERIORATING ALLOWING FOR WATER TO ENTER. DWELLING LACKS OPERATING SMOKE DETECTOR.
11/15/2005 INSP - FOLLOW UP CODE ENFORCE JHURD Correction Required 11/10/05, VISITED SITE TOOK PICTURES, FOUND ALL ISSUES ON NOTICE AND ORDER HAS BEEN COMPLETED EXCEOT ONE WHICH DEALS WITH PERMIT FOR ALTERED PLUMBING WATER LINES, EXPLAINED TO OWNER NEEDS PERMIT, OWNER STATED THAT PLUMBER STATED SHE DIDN'T, EXPLAINED TO OWNER REASON AND DOES NEED PERMIT, OWNER STATED WILL HAVE PLUMBER SECURE PERMIT. OFFICE FOLLOW UP ON PERMIT ONLY.

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00164
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/27/2005 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved 09-26-2005 CALLED PHONE NUMBER ON COMPLAINT FORM,LINE BUSY,VISITED SITE,NO ONE HOME,LEFT NO ONE HOME LETTER IN DOOR,FIVE DAYS TO RESPOND,DID NOTICE CARPORT ROOF APPEARS TO BE ADDED ,WATER LINES ALTERED,GAS LINES ALTERED,TOOK PICTURES. RESIDENT CAME HOME.THERE IS A SIXTY AMPERE SERVICE ENTRANCE THAT IS DOUBLE LUGGED,HAS NEW SERVICE FOR AIR CONDITIONER. TENANTS STATED THAT OWNER HAD SHUT WATER OFF TWO WEEKS AGO.TENANTS TURNED BACK ON. FENCE IS IN DELAPADATION.ELECTRICAL,TWELVE TWO ROMEX IS RUN FROM JUNCTION BOX TWO CEILING FANS(TWO)OUTLETS THREE PRONG POSSIBLE TWO WIRE SERVICE.LAUNDRY ROOM WORK WITHOUT PERMITS,WASHER AND DRYER HOOKED UP ILLEGAL-P-TRAP WRONG CONNECTIONS,NEW COPPER LINES,EXPOSED ROMEX,P.R. VALVE HOOKED INTO P. TRAP,GAS FLEX THRU THE WALL,TWO CONNECTORS TIED TOGETHER. CEILING HEIGHT AT SIX FOOT WALLS,GROUT IN TILE COMMING OUT.SMOKE DETECTORS DO NOT WORK,AIR GAP ON FRONT DOOR. ELECTRIC UNDER SINK FOR DISHWASHER IS INSTALLED INCORRECTLY.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00164
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
11/15/2005 CONTACTED BY PHONE
10/03/2005 NOTICE OF VIOLATION ISSUED
11/15/2005 COURT ORDERED ABATEMENT
11/15/2005 VIOLATION CLOSED