Case: T05DV00155

Parcel: 122081650


Addresses:

2213 N COLUMBUS BL

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
04/11/2005 INSP - INITIAL CODE ENFORCMENT Approved 4/11/05 VISITED SITE, MADE CONTACT WITH TENANT.CHECKED FOR POOL VIOLATIONS AS PER INTAKE FORM INFORMATION. STRUCTURE IS A RENTAL UNIT.
POOL VIOLATIONS:
(1) LACKING SELF CLOSING, SELF LATCHING HARDWARE
(2) POOL HAS APPROX 6" OF WATER AT SIDES AND TAPERS TO A DEPTH OF APPROX 2 1/2 FEET AT CENTER. GATES ARE LOCKED WITH PAD LOCKS AND HAS BARRIER FENCE 5 FT HIGH. SLIDING GLASS DOORS OPEN INTO POOL AREA.
ELECTRICAL: WORK W/O PERMITS
(1) MODIFICATION TO EXISTING I00 AMP SERVICE, 2 CIRCUITS HAVE BEEN ADDED, 1 CIRCUIT HAS EXPOSED ELECTRICAL CONDUCTOR NOT IN REQUIRED CONDUIT, LEADS TO J-BOX, THEN TO PORCH LIGHT AND OUTLET.
(2) EXTERIOR RECEPTICLE LACKS REQUIRED WEATHER PROTECTION
(3) 3-PRONG RECEPTICLE WAS TESTED AND FOUND TO HAVE OPEN GROUND.( LARGE ROOM,WEST WALL OF POSSIBLE ADDITION).
(4) OPEN J-BOX WITH EXPOSED ELECTRICAL CONDUCTOR NOT CAPPED OFF.
(5) OPEN GROUND FOUND IN ONE RECEPTICLE IN MIDDLE ROOM,POSSIBLE 2-WIRE SYSTEM HAS BEEN MODIFIED, 3-PRONG RECEPTICLE CHECKED OUT OK.
(6) KITCHEN EXHAUST FAN NOT WORKING.
(7) NO GFCI PROTECTION IN KITCHEN RECEPTICLE WITHIN 4 FT DUE TO MODIFICATION. GFCI PROTECTION WILL BE REQUIRED.
(8) RECEPTICLE BEHIND REFRIGERATOR LACKS COVER PLATE.
(9) THREE PRONG RECEPTICLE TESTED OK, BUT NOT GFCI PROTECTED.
(10) NO MECHANICAL GROUND FOR HEATER.
(11) EXPOSED LOW VOLTAGE CONNECTION IN FURNACE ROOM.
(12) BARRIER POOL LIGHT ON NORTH WALL HANGING BY ELECTRICAL CONDUCTORS.
ACCESS CONTROL:
SEVERAL WINDOWS WERE CHECKED AND LACK HANDLES FOR CRANKS, AND NOT WORKING THROUGHOUT STRUCTURE.
WEATHER STRIPPING:
(1) FRONT ENTRY DOOR HAS LARGE GAP AT BOTTOM OF DOOR.
(2) SEVERAL BROKEN WINDOWS THROUGHOUT STRUCTURE.
PLUMBING: WORK W/O PERMITS
(1) POSSIBLE ADDITION OF GAS LINE FOR DRYER, FURNACE AND HOTWATER HEATER.
(2) USING OLD VENT PIPE TO DRAIN WASHER, NOT AN APPROVED METHOD, AND LACKS P-TRAP.
(3) POSSIBLE ADDITION OF 1/2" WATER SUPPLY LINE FOR COLDWATER (COPPER).
(4) CRACKED CERAMIC TILE IN SHOWER RUNS FROM TUB UP TOWARDS WINDOW, APPROX 3 FT LONG.
(5) TRP DRAINS UP AND OUT OF CLOSET ABOVE ROOF.
MECHANICAL SYSTEM: COMBUSTION AIR AND FRESH AIR INTAKE ARE AS ONE, HAS NO SEPERATION. DOOR HAS TWO VENTS.
WORK WITHOUT PERMITS:
POSSIBLE ROOM ADDITION WITH ELECTRICAL, APPROX 15' X 40' HAS BEEN ATTACHED TO STRUCTURE, EVIDENCED BY USE OF EXTERIOR SEWER VENT DRAIN AND ADDITION OF GAS LINE AND WATER LINES.

CONTACT PERSONS: CATHY (TENANT)
325-4720