The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Case Details

Status:

CANCEL

Type:

RES: MINIMUM HOUSING

Entered Date:

02/25/2005

Applicant:

MC MANUS STEVEN

Description:

COMPLAINT:MIN HOUSING-POOL IS GREEN. PUMP NOT WORKING.

Outstanding Inspections

Case Number: T05DV00155
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 13
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - DETACHED STRUCTURES None Not Inspected
VIOL(BL) - ATTACHED STRUCTURES None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(FS) - EMERGENCY ACCESS None Not Inspected
NPO - EGRESS None Not Inspected

Completed Inspections

Case Status: CANCEL
Case Number: T05DV00155
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/11/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved 4/11/05 VISITED SITE, MADE CONTACT WITH TENANT.CHECKED FOR POOL VIOLATIONS AS PER INTAKE FORM INFORMATION. STRUCTURE IS A RENTAL UNIT. POOL VIOLATIONS: (1) LACKING SELF CLOSING, SELF LATCHING HARDWARE (2) POOL HAS APPROX 6" OF WATER AT SIDES AND TAPERS TO A DEPTH OF APPROX 2 1/2 FEET AT CENTER. GATES ARE LOCKED WITH PAD LOCKS AND HAS BARRIER FENCE 5 FT HIGH. SLIDING GLASS DOORS OPEN INTO POOL AREA. ELECTRICAL: WORK W/O PERMITS (1) MODIFICATION TO EXISTING I00 AMP SERVICE, 2 CIRCUITS HAVE BEEN ADDED, 1 CIRCUIT HAS EXPOSED ELECTRICAL CONDUCTOR NOT IN REQUIRED CONDUIT, LEADS TO J-BOX, THEN TO PORCH LIGHT AND OUTLET. (2) EXTERIOR RECEPTICLE LACKS REQUIRED WEATHER PROTECTION (3) 3-PRONG RECEPTICLE WAS TESTED AND FOUND TO HAVE OPEN GROUND.( LARGE ROOM,WEST WALL OF POSSIBLE ADDITION). (4) OPEN J-BOX WITH EXPOSED ELECTRICAL CONDUCTOR NOT CAPPED OFF. (5) OPEN GROUND FOUND IN ONE RECEPTICLE IN MIDDLE ROOM,POSSIBLE 2-WIRE SYSTEM HAS BEEN MODIFIED, 3-PRONG RECEPTICLE CHECKED OUT OK. (6) KITCHEN EXHAUST FAN NOT WORKING. (7) NO GFCI PROTECTION IN KITCHEN RECEPTICLE WITHIN 4 FT DUE TO MODIFICATION. GFCI PROTECTION WILL BE REQUIRED. (8) RECEPTICLE BEHIND REFRIGERATOR LACKS COVER PLATE. (9) THREE PRONG RECEPTICLE TESTED OK, BUT NOT GFCI PROTECTED. (10) NO MECHANICAL GROUND FOR HEATER. (11) EXPOSED LOW VOLTAGE CONNECTION IN FURNACE ROOM. (12) BARRIER POOL LIGHT ON NORTH WALL HANGING BY ELECTRICAL CONDUCTORS. ACCESS CONTROL: SEVERAL WINDOWS WERE CHECKED AND LACK HANDLES FOR CRANKS, AND NOT WORKING THROUGHOUT STRUCTURE. WEATHER STRIPPING: (1) FRONT ENTRY DOOR HAS LARGE GAP AT BOTTOM OF DOOR. (2) SEVERAL BROKEN WINDOWS THROUGHOUT STRUCTURE. PLUMBING: WORK W/O PERMITS (1) POSSIBLE ADDITION OF GAS LINE FOR DRYER, FURNACE AND HOTWATER HEATER. (2) USING OLD VENT PIPE TO DRAIN WASHER, NOT AN APPROVED METHOD, AND LACKS P-TRAP. (3) POSSIBLE ADDITION OF 1/2" WATER SUPPLY LINE FOR COLDWATER (COPPER). (4) CRACKED CERAMIC TILE IN SHOWER RUNS FROM TUB UP TOWARDS WINDOW, APPROX 3 FT LONG. (5) TRP DRAINS UP AND OUT OF CLOSET ABOVE ROOF. MECHANICAL SYSTEM: COMBUSTION AIR AND FRESH AIR INTAKE ARE AS ONE, HAS NO SEPERATION. DOOR HAS TWO VENTS. WORK WITHOUT PERMITS: POSSIBLE ROOM ADDITION WITH ELECTRICAL, APPROX 15' X 40' HAS BEEN ATTACHED TO STRUCTURE, EVIDENCED BY USE OF EXTERIOR SEWER VENT DRAIN AND ADDITION OF GAS LINE AND WATER LINES. CONTACT PERSONS: CATHY (TENANT) 325-4720
07/20/2005 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved NOV MAILED .NHARTMAN

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00155
Case Status: CANCEL
Total Completed Case Activity Conditions: 4
Date Name
09/07/2005 CONTACTED BY PHONE
03/15/2006 CONTACTED IN PERSON
09/09/2005 NOTICE OF VIOLATION ISSUED
06/08/2006 CITATION ISSUED

Documents

File Name Document Type  
NOTES 08-22-06.PDF DOCUMENTS VIEW
2213 N COLUMBUS BL 2006-04-03 002.JPG IMAGES VIEW
2213 N COLUMBUS BL POOL VIO 2006-04-03 007.JPG IMAGES VIEW
2213 N COLUMBUS BL 2006-04-03 001.JPG IMAGES VIEW
2213 N COLUMBUS BL BATH RM REHAB 2006-04-03 017.JP IMAGES VIEW
2213 N COLUMBUS BL BATH RM REHAB 2006-04-03 018.JP IMAGES VIEW
2213 N COLUMBUS BL DRIED COMBUS REMOVED 2006-04-03 IMAGES VIEW
2213 N COLUMBUS BL HAZ ELECT 2006-04-03 011.JPG IMAGES VIEW
2213 N COLUMBUS BL HAZ ELECT 2006-04-03 005.JPG IMAGES VIEW
2213 N COLUMBUS BL HAZ ELECT LACKS DRIP LOOP & TEP IMAGES VIEW
2213 N COLUMBUS BL HAZ ELECT LACKS PROTECTION 2006 IMAGES VIEW
2213 N COLUMBUS BL HAZ MECH WOP 2006-04-03 016.JPG IMAGES VIEW
2213 N COLUMBUS BL HAZ PLUMBING W O P 2006-04-03 0 IMAGES VIEW
2213 N COLUMBUS BL KITCHEN RESTORED 2006-04-03 004 IMAGES VIEW
2213 N COLUMBUS BL LACKS SELF CLOSING HD 2006-04- IMAGES VIEW
2213 N COLUMBUS BL LACKS SELF CLOSING HD 2006-04-0 IMAGES VIEW
2213 N COLUMBUS BL NEW FLR 2006-04-03 003.JPG IMAGES VIEW
2213 N COLUMBUS BL PLUMBING WOP 2006-04-03 021.JPG IMAGES VIEW
2213 N COLUMBUS BL REHAB INTER 2006-04-03 008.JPG IMAGES VIEW
2213 N COLUMBUS BL REHAB INTER 2006-04-03 009.JPG IMAGES VIEW