Permit: T05CM06362

Parcel: 110121360

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/05/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/06/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/01/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER TEST DWV OK
SUPPORT WASTE PIPING AT P-4, SECURE VENT W/MIDSTORY STRAP.
INSTALL SAFETY STRAPS WHERE PIPING PASSING THRU STUDS ARE WITHIN 1 1/4".
CW WATER PIPING TO BA2 IS 1/2", PLAN CALLS FOR 3/4"
CLOSET FLANGES SHALL BE FASTENED TO FOOR AND SHALL REST ON A FIRM BASE WITH TOP OF FLANGE 1/4" ABOVE F.F THIS CAN BE INSPECTED AFTER TILE.