Permit: T05CM06180

Parcel: 14022003K

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/16/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*LOOKS GOOD THANKS BE SURE TO MAKE CLEANOUT PLUG WATER AND GAS TIGHT WITH THE USE OF APPROVED COMPOUND OR TAPE
02/09/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SECURE COPPER WATER SUPPLY TO KIT. WITH APPROVED HANGARS/PIPE SUPPORTS
USE OF SWEEP REQUIRED ON TRAP ARM
CLEAN OUT PLUG SHALL BE MADE WATER TIGHT W/THE USE OF TEF TAPE OR APPROVED THREAD COMPOUND
NOTE: BALL VALVES IN WALL WILL REQUIRE ACCESS.
PROVIDE WATER TEST ON SHOWER PAN BY PLUGGING THE DRAIN AND FILLING W/WATER TO FLOOD RIM.