Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM05879
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED LETTER DELETING ROOF CANOPY AND RAIN DRAINS ON NORTH SOUTH CANOPIES -- (303) 525-9352 |
|
06/27/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE PLUMBING WORK PROVIDE BACK FLOW VERIFICATIONS 2) PROVIDE ACCESS TO CLEANOUTS IN MEAT AND SEAFOOD SINKS (2) |
|
06/06/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. PROVIDE INSULATION ON HOT PIPING PER PLAN. 2. PROVIDE BACKFLOW PROTECTION ON HAND SPRAYER WITH CERTIFICATION AT PAN WASHER. 3. PROVIDE BACKFLOW PROTECTION FOR ICE MACHINE & POTABLE WATER TO SODA DISPENSER WITH CERTIFICATION. 4. SUPPORT WATER PIPING ON OVENS AND REMOVE ALL DEBRIS. |
|
06/05/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 03035 -- WATER PIPING IN BAKERY OK NEED INSULATION ON HOT PIPING IN BAKERY. 03090 -- PARTIAL FOR FIXTURES IN BAKERY ONLY GAS SYSTEM SHALL BE COMPLETE & TESTED & APPROVED BY ALL CONCERNED TO OCCUPY THIS AREA. |
|
05/16/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* MEAT BOX & MEAT ROOM INTERMEDIATES FINAL OK PENDING CITY APPROVAL OF REVISED YET TO BE APPROVED PLAN. DATE 5/4/06 RICHARD JOACHIM |
|
04/20/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* STARBUCKS 3-COMP SINK DRAIN, SANITIZE BOWL TO BE SEPARATE DRAIN FROM WASH & RINSE DRAIN. PHARMACY WATER HEATER REQUIRES CORRECT SUPPORT FOR PAN DRAIN A T&P TO GRAVITY DRAIN TO FLOOR SINK. (3) IN HOUSE BACKFLOW CERTIFICATIONS FOR STARBUCKS. |
|
04/19/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
04/17/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE INSPECTION OF CONTINUATION OF WATER PIPING FOR STARBUCKS, SUPPORTED CORRECTLY TO POINT OF CONNECTION. 2. DRAINS FROM APPLIANCES TO BE GRAVITY, RIDGID PIPING SEPARATE DRAINS. 3. PROVIDE BACKFLOW PROTECTION FOR ICE MACHINE, ESPRESSO MACHINES, COFFEE MAKERS, WITH CERTIFICATIONS. 4. PROVIDE SEPARATE DRAINS FOR ICE BIN & MAKER IF REQUIRED FROM ICE MAKER. 5. FAUCET FOR 3-COMP SINK TO HAVE BACKFLOW PROTECTION OR CORRECT MEANS TO PROVIDE NO SUBMERGED INLET FOR HAND SPRAYER. 6. PLEASE PROVIDE LISTING SHEET FOR R.O. UNIT. |
|
04/10/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* FLORAL AREA OK |