Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM05879
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
06/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE REVISED PLAN DELETING RAIN DRAINAGE APPROVED BY CITY |
|
06/19/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* INTERMEDIATE IN DELI OK |
|
06/14/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 5 FLOOR SINKS PERMANENTLY CAPPED VENTS PROPERLY CAPPED VENT ON NORTH WALL TIED INTO EXISTING. PLEASE ADD SUPPORTS ON OVERHEAD EXISTING VENT. INSTALL FHA STRAPS WHERE NEEDED. OK TO COVER. CLEAN OUT ADDED ON HAND SINK WASTE. MAKE WATER TIGHT. |
|
05/31/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
05/24/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* INSTALL OF VENTS THRU ROOF IN BAKERY OK WATER TO SOFTENER & BACK UP TO CEILING OK - IN BAKERY WATER TO CHILLER & TO ABOVE CEILING OK IN BAKERY 1. NEED TO SEE ABOVE CEILING IN BAKERY PRIOR TO CEILING TILE. |
|
05/23/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* BAKERY CAPS ON DEMO THIS AREA OK WATER PIPING IN WALL BAKERY AREA EXCEPT SOFTENER OK WASTE & VENT TO ABOVE WALL FRAME OK 1. DO NOT LEAVE ANY SANITARY DRAINS, VENTS ETC OPEN TO INSIDE OF STORE. 2. SUPPORT OVERHEAD WATER PIPING USING APPROVED MATERIALS & METHODS. 3. PROVIDE TEST ON VENTS THRU ROOF. |
|
05/05/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 5 PSI AIR TEST ON REVENTS ABOVE MEAT COOLER OK. PROVIDE STURDY SUPPORTS FOR HORIZONTAL ABS. 100 PSI AIR TEST ON WATER PIPING. |
|
05/02/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
04/19/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
04/12/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/10/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/06/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* TEST ON 2" PHARMACY SINK DRAIN TO 15' AFF OK CAP ON EXISTING RELOCATED FLOOR SINK OK AIR TEST UNDERGROUND RELOCATED FLOOR SINK ABOVE BY PHARMACY 1/2" WATER TO PHARMACY SINK TO 15' ABOVE FINISH FLOOR OK AIR TEST OK |
|
04/05/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* TEST ON 2" FLOOR SINK DRAIN & VENT TO POINT OF CONNECTION PER REDLINE IN FLORAL AREA OK |