Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM05879
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/27/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
06/13/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
05/22/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* NEW UNDERGROUND FOR BAKERY AREA OK 1. NEED TO SEE ALL DEMO CAPS IN THIS AREA BEFORE CONCRETED BACK IN. 2. WILL NEED TEST THRU ROOF ALL VENTS. |
|
05/02/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* VENT FROM DAIRY COOLER FLOOR SINK OK T&P DRAIN & PAN DRAIN FROM WATER HEATER ON DAIRY COOLER OK UNDERGROUND GREASE WASTE & SANITARY WASTE IN MEAT BOX & MEAT ROOM OK |
|
05/01/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* COULD NOT DO P.M. INSPECTION TODAY SORRY |
|
04/25/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* RED LINE OF PRODUCE PROP. 4" FLOOR SINK ADDITION PER DELTA 4 DATED 4/17/06 RICHARD JOACHIM WATER TEST OK PENDING REVISED CITY APPROVAL. RED LINE OF MEAT ROOM TO 2' SOUTH OF 2" to 4" GREASE WASTE WATER TEST MY INITIAL ON PLAN. SHALL REQUIRE CITY APPROVED REVISED PLAN. SANITARY DRAINAGE FOR SEAFOOD PROP #6 P1.4 FOR (2) 2" FLOOR SINKS AND MA106 LAV WATER TEST REDLINE SHALL BE REVISED CITY APPROVED. PROVIDE REDLINES AT ISOMETRIC DRAWING FOR INTERMEDIATE PIPING. PROVIDE REVISED APPROVED PLAN SOON FIXTURES ARE BEING MOVED AND ADDED TOO MUCH TO CONTINUE AS REDLINE ON THIS PROJECT. |
|
04/24/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE TEST PROVIDE CORRECT DRAINAGE FITTINGS ON VENTS BELOW FLOOD LEVEL. CORRECT SLOPE ON SANITARY LINE - 2 1/2 MIN. |
|
04/21/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PHARMACY SINK IS OK FOR FINAL |
|
04/19/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* CONTINUATION OF 2" DRAINAGE FOR DRINKING FOUNTAIN TO POINT OF CONNECTION OF EXISTING BUILDING DRAIN TEST OK WATER PIPING & VENT IN WALL TO 10' OK SAME AREA. |
|
04/18/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PROVIDE FLOOR SINKS & BAKERY GOODS FLOOR SINK OK 2" VENT FROM BAKERY SINK NEEDS TO E COMPLETED WITH TEST. |
|
04/17/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 2" DRINKING FOUNTAIN DRAIN FROM DRINKING FOUNTAIN THRU WALL WITH VENT TO 10' AFF PARTIAL. 1. NEED REVISED APPROVED PLAN AND CONTINUATION OF DRAIN & VENT. WATER PIPING TO 10' PARTIAL. |
|
04/12/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* FLOOR SINK CENTER OF PRODUCE OK FLOOR SINK FOR BAKERY CASE WITH VENT PER REDLINE ON SITE OK |
|
04/11/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* (2) FLOOR SINKS PARTIAL TO 8' CONNECTION TO EXISTING AT PRODUCE CASE LINE OK 2" VENT FROM BAKERY CASE FLOOR SINK AREA PARTIAL, SUPPLY RED LINE AND FUTURE REVISED APPROVED PLAN. |
|
04/10/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* NEW 3" VENT UNDERGROUND FOR PRODUCE CASES AT EAST END OK (3) 3" COMBO WASTE & VENT FLOOR SINKS AT EAST END PRODUCE CASES UNDERGROUND OK |
|
04/06/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
04/05/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/30/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 5 PSI AIR TEST ON UNDERGROUND AT STARBUCKS AREA OK 2- 3/4" WATER SUPPLIES COOPED INTO SAME AREA OK |
|
03/29/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ISLAND DRAWING IN FLORAL UNDERGROUND WATER TEST OK |
|
03/28/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* AIR TEST (4) FLOOD SINKS IN FROZEN FOOD CASE AREA (CENTER STORE) OK |
|
03/27/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE APPROVED P-TRAPS 2. PROVIDE APPROVED PLASTIC X PLASTIC COUPLING & TRANSITION COUPLINGS. 3. COMBINATION WASTE & VENT SHALL BRANCH OFF MAIN ON HORIZONTAL WITH 1 OFFSET TO DECREASE TAILPIECE LENGTH. 4. PROVIDE APPROVED TEST MEANS FOR PIPING. |
|
03/24/2006 | PLUMBING - ROUGH, SOIL | Cancelled | IVRS - RI canceled |