Permit: T05CM05879

Parcel: 141148150


Addresses:

9050 E VALENCIA RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T05CM05879

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/27/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
06/13/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
05/22/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
NEW UNDERGROUND FOR BAKERY AREA OK
1. NEED TO SEE ALL DEMO CAPS IN THIS AREA BEFORE CONCRETED BACK IN.
2. WILL NEED TEST THRU ROOF ALL VENTS.
05/02/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
VENT FROM DAIRY COOLER FLOOR SINK OK
T&P DRAIN & PAN DRAIN FROM WATER HEATER ON DAIRY COOLER OK
UNDERGROUND GREASE WASTE & SANITARY WASTE IN MEAT BOX & MEAT ROOM OK
05/01/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
COULD NOT DO P.M. INSPECTION TODAY SORRY
04/25/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
RED LINE OF PRODUCE PROP. 4" FLOOR SINK ADDITION PER DELTA 4 DATED 4/17/06 RICHARD JOACHIM WATER TEST OK
PENDING REVISED CITY APPROVAL. RED LINE OF MEAT ROOM TO 2' SOUTH OF 2" to 4" GREASE WASTE WATER TEST MY INITIAL ON PLAN. SHALL REQUIRE CITY APPROVED REVISED PLAN. SANITARY DRAINAGE FOR SEAFOOD PROP #6 P1.4 FOR (2) 2" FLOOR SINKS AND MA106 LAV WATER TEST REDLINE SHALL BE REVISED CITY APPROVED. PROVIDE REDLINES AT ISOMETRIC DRAWING FOR INTERMEDIATE PIPING. PROVIDE REVISED APPROVED PLAN SOON FIXTURES ARE BEING MOVED AND ADDED TOO MUCH TO CONTINUE AS REDLINE ON THIS PROJECT.
04/24/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE TEST
PROVIDE CORRECT DRAINAGE FITTINGS ON VENTS BELOW FLOOD LEVEL.
CORRECT SLOPE ON SANITARY LINE - 2 1/2 MIN.
04/21/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PHARMACY SINK IS OK FOR FINAL
04/19/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
CONTINUATION OF 2" DRAINAGE FOR DRINKING FOUNTAIN TO POINT OF CONNECTION OF EXISTING BUILDING DRAIN TEST OK
WATER PIPING & VENT IN WALL TO 10' OK SAME AREA.
04/18/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PROVIDE FLOOR SINKS & BAKERY GOODS FLOOR SINK OK
2" VENT FROM BAKERY SINK NEEDS TO E COMPLETED WITH TEST.
04/17/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
2" DRINKING FOUNTAIN DRAIN FROM DRINKING FOUNTAIN THRU WALL WITH VENT TO 10' AFF PARTIAL.
1. NEED REVISED APPROVED PLAN AND CONTINUATION OF DRAIN & VENT. WATER PIPING TO 10' PARTIAL.
04/12/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
FLOOR SINK CENTER OF PRODUCE OK
FLOOR SINK FOR BAKERY CASE WITH VENT PER REDLINE ON SITE OK
04/11/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
(2) FLOOR SINKS PARTIAL TO 8' CONNECTION TO EXISTING AT PRODUCE CASE LINE OK
2" VENT FROM BAKERY CASE FLOOR SINK AREA PARTIAL,
SUPPLY RED LINE AND FUTURE REVISED APPROVED PLAN.
04/10/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
NEW 3" VENT UNDERGROUND FOR PRODUCE CASES AT EAST END OK
(3) 3" COMBO WASTE & VENT FLOOR SINKS AT EAST END PRODUCE CASES UNDERGROUND OK
04/06/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
04/05/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
03/30/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
5 PSI AIR TEST ON UNDERGROUND AT STARBUCKS AREA OK
2- 3/4" WATER SUPPLIES COOPED INTO SAME AREA OK
03/29/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
ISLAND DRAWING IN FLORAL UNDERGROUND WATER TEST OK
03/28/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
AIR TEST (4) FLOOD SINKS IN FROZEN FOOD CASE AREA (CENTER STORE) OK
03/27/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED P-TRAPS
2. PROVIDE APPROVED PLASTIC X PLASTIC COUPLING & TRANSITION COUPLINGS.
3. COMBINATION WASTE & VENT SHALL BRANCH OFF MAIN ON HORIZONTAL WITH 1 OFFSET TO DECREASE TAILPIECE LENGTH.
4. PROVIDE APPROVED TEST MEANS FOR PIPING.
03/24/2006 PLUMBING - ROUGH, SOIL Cancelled IVRS - RI canceled