Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/10/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 06/26/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PLUMBING AT WATER CLOSETS NEEDS TO BE REDONE OK TO COVER ALL OTHER AREAS -- UNDERGROUND ONLY 2. GAS PRESSURE TEST OK |
|
| 03/13/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PLEASE RE-POST YOUR ADDRESS 2. NOT READY FOR INSPECTION 3. DBL COMBO MAY NOT LAY ON ITS BACK HORIZ. VENTING BELOW FLOOD RIM LIMITED TO STRUCTURAL CONDITIONS 4. PIPING TO BE LAIN ON A FIRM BED. 5. 2 WAY CLEANOUT FITTING UNDER SLAB FOR TEST NOT APPROVED. 6. TEST ENTIRE UNDERGROUND. IF THERE IS A PROBLEM WITH THE EXISTING DON'T YOU WANT TO KNOW ABOUT IT NOW RATHER THAN LATER? |
|
| 02/15/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*3" floor sink w/ cast iron p trap w/trap primer at meat case location ok water tested to 10' | |
| 02/14/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TRANSITION FROM CAST IRON FLOOR SINK TO ABS REQUIRES A MISSION COUPLING OR USE CAST IRON BETWEEN CAST IRON P TRAP & FLOOR SINK. - PROVIDE A 10' WATER TEST - PROVIDE PERM CAP AND CAPPABLE TEST WYE AT TEST WYE LOCATION |
|
| 02/13/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* MISSION COUPLING REQUIRED AT TRANSITIONS FROM CAST IRON TO PLASTIC N/H COUPLING OK AT CAST TO CAST PROVIDE WATER TEST ON NEW PIPING. |
|
| 01/29/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*PLEASE RE POST YOUR ADDRESS PLAN IS NOT REFLECTIVE OF THE INSTALLATION, NEW 3" FLOOR SINK IS EXISITING, WITH NO VENT. HANDSINK IS EXISTING WITH EXISTING FLOOR SINK BELOW ( NOT SHOWN ON THE PLAN) PLEASE CLARIFY THE PLAN TO SHOW ALL NEW, AND ALL EXISTING PLUMBING VENT CONNECTED TO HORIZONTAL DRAIN TO HAVE ITS INVERT ABOVE DRAINAGE CENTER LINE. FURNCO NOT PERMITTED N/H BANDS NOT PERMITTED REINSPECTED NUMBER FIVE ABOVE CORRECTEDNUMBER FOUR ABOVE CORRECTED OK TO COVER TO 3" FLOOR SINK |