Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 09/28/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 35/36 WB OK TO COVER AFTER 4 INSPECTIONS |
|
| 09/27/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 33-36 OK TO COVER INTERIOR WALLS, MAINTAIN VALVE ACCESS. 33 HAS TWO PLACES REQUIRING ACCESS 35/36 WASHER BOX PIPING NOT SECURED AND TOUCHING METAL. |
|
| 09/26/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - DO NOT BUNDLE HOT & COLD, MET W/SANDERS PLUMBING - INSTALL ISOLATORS - COMPLETE CORRECTIONS FROM PREVIOUS INSP. - PROVIDE INSTALLATION INSTRUCTIONS FROM TUB |
|
| 09/24/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - COPPER TOUCHING METAL - DO NOT STRAIN TUBING - NAIL CLIPS ON PEX AT STUD PENETRATIONS NOT PROPERLY INSTALLED - DON'T STRAIN OR FORCE CV OR PEX - USE ISOLATORS - INSTALL BACKING AND SECURE DROP EAR ELLS AND TUB DIVERTORS; KEEP OPEN DRAINS PLUGGED. PEOPLE LIVE IN THIS BUILDING! |
|
| 08/30/2007 | PLUMBING - INTERMEDIATE | Partial Approval | UNIT 38 - C.O OK TUB NOT DRAINING | |
| 08/29/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/29/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* USE WYE PATTERN FITTING ON CO EXTENSION |
|
| 06/01/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT #28 OK TO COVER WALLS KITCHEN EXTENSION MADE OK |
|
| 05/24/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/22/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/02/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 32 OK TO COVER PROVIDE ACCESS FOR TUB WASTE & OVERFLOW |
|
| 01/16/2007 | PLUMBING - INTERMEDIATE | Cancelled | CANCELLED PER STEVE #406-3632 | |
| 01/16/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 41 OK TO COVER PIPING EXTENDED AT KIT SINK ALL OTHER AREAS IN EXISTING CONDITION |
|
| 08/29/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 29 OK TO COVER SOME UNITS ARE OCCUPIED, YOU NEED TO INSTALL HB VAC BREAKERS ON ALL HBS TO PREVENT THE CONTAMINATION OF THE WATER SUPPLY. |
|
| 07/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SEE NOTES FROM ACTIVITY ...4757 |