Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 12/20/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK FINAL 33, 34, 35, 36 S.T.O.I CHECK 30 & 39? |
|
| 12/18/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING SMOKE DETECTORS 2. MISSING EXHAUST FANS |
|
| 11/29/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 10/25/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 10/23/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CANCELLED |
|
| 09/21/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/24/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK #43 SUBJECT TO OTHER INSPECTORS |
|
| 08/23/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* #43 1. KITCHEN GFCI NOT WORKING ALSO OUTSIDE 2. CLEAN EXCESS DIRT FROM PANEL 3. ARE BOTH KITCHEN CIRCUITS ON THE SAME POLE AND WHERE ARE BEDROOM RECEPTACLES 4. PO PLANS CALL FOR LIGHT AT SIDE DOOR AS PER 210.70 |
|
| 08/13/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/10/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) OK #28 STOI |
|
| 08/08/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK #32 |
|
| 08/07/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/06/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/03/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* RECEIVED CK#1214 FOR $108.00 OK #42 |
|
| 08/02/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK 31 |
|
| 07/26/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK UNIT #29 SUBJECT TO OTHER INSPECTORS |
|
| 07/22/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/21/2007 | ELECTRIC - FINAL | Denied | RECEIVED CK#1201 FOR $432.00 ALL ROOF UNITS - CHECK IDENTIFICATION OF UNGROUNDED CONDUCTOR, SUPPORT OF SEALTITE, LOOSE FITTINGS AND LABELING OF UNITS. #27 -- OK INTERIOR #29 -- A. BOXES MORE THAN 1/4" FROM BOX TO SURFACE 314.20 B. INSTALL NEUTRALS TO NEUTRAL BAR - USE APPROVED COPPER TO ALUMINUM SPLICES C. SEPARATE GROUND & NEUTRAL A/C JUNCTION BOX #32 -- A. PROTECT CABLE/CORD FROM SHARP METAL EDGES - HOOD B. MOUNTING SCREW FOR COVER NOT AN APPROVED GROUNDING METHOD C. BOXES MORE THAN 1/4" FROM BOX TO SURFACE #42 A. OUTSIDE RECEPTACLE NOT GFCI PROTECTED B. BOXES MORE THAN 1/4" FROM BOX TO SURFACE C. IS THERE A COVERED JUNCTION BOX FOR BATH LIGHT #37 A. BOXES MORE THAN 1/4" FROM BOX TO SURFACE B. MISSING SMOKE DETECTORS HALL & BEDROOM C. LABEL PANEL AS PER 408.4 |
|
| 02/11/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK UNIT #41 1. CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS |
|
| 02/07/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/04/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK FINAL APT #211 |
|
| 07/28/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* #405 1. TIGHTEN LOOSE FITTINGS 2. SWITCHES TO BE GROUNDED 3. SUPPORT SEALTITE 4. MISSING DEAD FRONT COVER A/C DISCONNECT 5. SPLIT BOLT LISTED 2 CONDUCTORS 6. A BOND BUSHING IS NEEDED 250.92 |