Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM04691
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
11/09/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* AFTER HRS. INSP. RICHARD 240-2459 PAID W/CHK #1305 RECEIVED BACTERIA TEST REPORT RECEIVED 4 INTERNAL 009 TEST REPORTS RECEIVED 1 SERVICE PROTECTION TEST REPORTS. RECEIVED PCWM AUTHORIZATION TO DISCHARGE #01923 VERIFICATION OF GRADE PERFORMED BY ARROW LAND SURVEY BOILER INSPECTED BY INDUSTRIAL COMM. OF AZ ON 11/8/06 -- AZ 810446 NO OBVIOUS SAFETY HAZARDS PRESENT OTHER THAN COMPLETING MANHOLE. |
|
11/08/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PSI TEST FROM ? MAN HOLE TO MAN HOLE #1 2) VACUUM BREAKER INSTALLED ON HOSE BIB 3) CORRECT BACKFLOW PROTECTION WAS INSTALLED AT BATCH PLANT AND FUTURE BOILER 4) NEED TO PROVIDE BACKFLOW CERTS 5) DISCHARGE PERMIT IS ON SITE 6) BACTERIA REPORT-PROVIDE ADDRESS ON REPORT FOR JOB SITE |
|
11/03/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
11/02/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) POTABLE SYSTEM CURRENTLY BEING ? 2) VACUUM BREAKER REQUIRED AT NORTH EAST HOSE BIB 09/27/06 NOTES 3) PLEASE CALL IN AND HAVE APPROVED ALL UN APPROVED INSPECTIONS PERTAINING TO PLUMBING 4) SHALL PROVIDE CORRECT BACKFLOW PROTECTION FOR DEGREE OF PROTECTION REQUIRED 5) BATCH PLANT, FUTURE BOILER WHICH IS ON SITE AT FUTURE LOCATION 6) FUTURE BOILER SHALL HAVE CITY APPROVED PLAN AND PERMITS WITH ? BOILER INSPECTION WHEN ? INSTALLED |
|
09/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ALL POTABLE WATER HOSE BIBS TO HAVE VACUUM BREAKERS. NO WATER CONNECTION TO BUILDING AT THIS TIME. PROPER BACKFLOW FOR EQUIPMENT SHALL BE INSTALLED FOR POTABLE WATER SYSTEMS. |
|
07/07/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RESTROOMS #117 & 129 WATER PIPING OK |
|
06/16/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NEED TO SEE WATER PIPING FOR PLUMBING INTERMEDIATE OK TO COVER TIE IN OUTSIDE BUILDING. |
|
06/01/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLEAN OUTS OK PIPE INSULATION IS OK |
|
05/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WYE PATTERN FITTINGS REQUIRED FOR CLEAN OUT EXTENSIONS. TEST ON DWV OK 100 PSI TEST ON WATER OK OVERHEAD PIPING OK OK TO INSULATE CLOSET FLANGES NOT SET. |