Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T05CM04672
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/12/2005 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* | |
10/11/2005 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :*SOIL WATER TEST IS OK FOR P-4, P-13-? IN ROM # 107. P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK OK TO BACKFILL THIS AREA ONLY CANNOT USE A WYE AND BELL REDUCER FOR TRAP ARM @ P-4 IN RM # 111. THIS TRAP ARM SHALL BE 1 1/2" ALL THE WAY TO THE BARREL AND PROVIDE A 2 X 1 1/2 SAN TEE RETEST THE SYSTEM SHALL PROVIDE A HANGER OR STRAP FOR HORIZONTAL VENT ABOVE CEILING |