Inspection History: SITE - SEWER

Date Description Inspector Results Comments
04/03/2006 SITE - SEWER Approved IVRS - Inspection :*
03/08/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
OK TO COVER
PROVIDE GREEN TRACER WIRE
PROVIDE CLEAN OUT ADAPTORS W/PLUGS
03/07/2006 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOT HOLDING TEST
03/03/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
1) POST YOUR ADDRESS
2) CORRECT BACK PITCH WHERE LINE COMES OUT OF SLEEVE UNDER TRACKS
3) WEST RUN LAID AT 50 PERCENT PER PLAN
4) ENTIRE WEST RUN WILL NEED TO DROP TO PROVIDE ADEQUATE-SLOPE THROUGHOUT
5) PIPING SOUTH OF TRACKS OK TO COVER
6) 3 PSI AIR TEST HOLDING