Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 04/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINTEL OVER EAST ENTRY OK |
|
| 03/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4'-9' EAST SCREEN WALL 8'-12' WEST STAIRWAY |
|
| 03/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWAY WALLS (4'-8') |
|
| 03/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST STAIRWELL WALLS (0-4'); GENERATOR ENCLOSURE & N. SCREEN WALL (4'-8'8"); ELEVATOR (24'-28') |
|
| 03/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 2/C-E, 3/F-H, 4/D-H, C/2-3, C/3.5-4, H.3-4 (28'-31'4"); ELEVATOR (20'-24') |
|
| 03/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT AT GRID 4-H, 3-F SITE WALL FOR GENERATOR TOPOUT |
|
| 03/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) I LINE 3-4, 3-J-F, F-2-3, 2-F-L, C-2-3 28' LIFT |
|
| 02/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*24' LIFT ON SOUTH WALL | |
| 02/27/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GRID LINE J-B-4, LINE 3-J-F, LINE F-3-2, LINE 2-F-C, LINE C-3-2 ALL 24"/ELEVATOR 16' |
|
| 02/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 2/C-F, 3/F-H, C/2-3, F/2-3, H/3-4 (16'-20'); 4/B-H, C/3.5-4 (20'-24') |
|
| 02/23/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* NO ACCESS TO PLANS |
|
| 02/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 2-CF, F-2-3, 3-H-F, H-3-4, 4-B-H, C-2-3, C-3, C4 12'-16' ELEVATOR WALL 8'-12' |
|
| 02/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*GRIDLINE 4 AND C 16' LIFT | |
| 02/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*TOP OUT GRID LINE 6 & 7 A-H LINE B 7-4 H-7-4 | |
| 02/10/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE H-6-4, 3-1 8'-12', LINE 1 C-A TOP OUT LINE A-1-3; TOP OUT LINE 3 A-C TOP OUT ELEVATOR SHAFT 4'-8' LINE 6-7 A-H 8'-12' |
|
| 02/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*3RD LIFT SOUTH WALL, TSPOUT NORTH WEST WALL 40' | |
| 01/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*3RD LIFT GRIDLINES 1-3 F.C LINE 4B | |
| 01/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*GRIDLINES 1-3 F.C LINE 4,B. PARTIAL 8'LIFT OK | |
| 01/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT EXCLUDES SOUTHWEST CORNER |
|
| 01/18/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRID LINE H-4 LINE A-H-4 |