Permit: T05CM04175

Parcel: 108240870


Addresses:

2490 E RIVER RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
07/25/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
04/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINTEL OVER EAST ENTRY OK
03/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4'-9' EAST SCREEN WALL
8'-12' WEST STAIRWAY
03/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST STAIRWAY WALLS (4'-8')
03/08/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST STAIRWELL WALLS (0-4'); GENERATOR ENCLOSURE & N. SCREEN WALL (4'-8'8"); ELEVATOR (24'-28')
03/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 2/C-E, 3/F-H, 4/D-H, C/2-3, C/3.5-4, H.3-4 (28'-31'4"); ELEVATOR (20'-24')
03/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT AT GRID 4-H, 3-F SITE WALL FOR GENERATOR TOPOUT
03/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) I LINE 3-4, 3-J-F, F-2-3, 2-F-L, C-2-3 28' LIFT
02/28/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*24' LIFT ON SOUTH WALL
02/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) GRID LINE J-B-4, LINE 3-J-F, LINE F-3-2, LINE 2-F-C, LINE C-3-2 ALL 24"/ELEVATOR 16'
02/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 2/C-F, 3/F-H, C/2-3, F/2-3, H/3-4 (16'-20'); 4/B-H, C/3.5-4 (20'-24')
02/23/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NO ACCESS TO PLANS
02/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 2-CF, F-2-3, 3-H-F, H-3-4, 4-B-H, C-2-3, C-3, C4 12'-16' ELEVATOR WALL 8'-12'
02/15/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*GRIDLINE 4 AND C 16' LIFT
02/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TOP OUT GRID LINE 6 & 7 A-H LINE B 7-4 H-7-4
02/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GRIDLINE H-6-4, 3-1 8'-12', LINE 1 C-A TOP OUT LINE A-1-3; TOP OUT LINE 3 A-C TOP OUT ELEVATOR SHAFT 4'-8' LINE 6-7 A-H 8'-12'
02/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*3RD LIFT SOUTH WALL, TSPOUT NORTH WEST WALL 40'
01/31/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*3RD LIFT GRIDLINES 1-3 F.C LINE 4B
01/25/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*GRIDLINES 1-3 F.C LINE 4,B. PARTIAL 8'LIFT OK
01/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT EXCLUDES SOUTHWEST CORNER
01/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GRID LINE H-4 LINE A-H-4