Permit: T05CM04146

Parcel: 140430130

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T05CM04146

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/18/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
PRESLAB OK
4" RWL AND ORWC AT SE CORNER UNDER SIDEWALK OK
04/17/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PRESLAB KIT AREA OK
04/10/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
UNDERGROUND IN BUILDING OK
RECALL PRIOR TO CONCRETE FOR PIPE WRAP INSPECTION.
04/07/2006 PLUMBING - ROUGH, SOIL Cancelled
04/05/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
4" SANITARY ALONG COL 3, BETWEEN L-5 AND M
04/03/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
4" GREASE WASTE MAIN THRU BUILDING AT 1% OK PER ENGINEER.
GREASE FIXTURE WASTE PIPING SOUTH OF COL 3.5 - OK
SANITARY PIPING SOUTH OF 3.5 AND WEST OF COL M.
CLEAN OUT ADDED AT UPPER TERMINAL OF 4"
03/31/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
03/30/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- 4" GREASE WASTE IS INSTALLED AT 1% SLOPE
- 2% SLOPE IS POSSIBLE ON GREASE LINE.
- PROVIDE 2% OR PROVIDE A STAMPED DOCUMENT ALLOWING GREASE WASTE TO RUN AT 1%
- 4"-6" SANITARY SEWER IS RUN AT 1% PROVIDE APPROVAL FROM MECHANICAL ENGINEERS.
- PROVIDE A FULL SIZED CLEAN OUT ON 4" SANITARY WASTE AT SOUTH END OF RUN IN KITCHEN AREA.
- CORRECT VENT FOR 3" TROUGH DRAIN.
02/17/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTE CALL DWIGHT @ 401-1351 10 MIN PRIOR TO INSPECTION
ENTER 805 GATE OF ARROW PARK BLVD
PLAN CALLS FOR 4" RWL, REDUCE AT RD CONNECTION