Permit: T05CM02739

Parcel: 11306203A

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/13/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
AIR BALANCE OK
05/23/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE BALANCE REPORT
2. CONDENSING UNITS STANDS NOT PROPERLY SUPPORTED PROVIDE SUPPORT 90 DEG. OF TRUSSES
3. SEAL LINE SET PENETRATIONS THROUGH WALL
4. LOW VOLTAGE WIRING TO BE ADEQUATELY SUPPORTED SO AS TO BE OFF ROOF.
05/22/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
05/08/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
PROVIDE AIR BALANCE REPORT
PERMANENTLY ID EQUIPMENT ON ROOF AND ABOVE CEILING
PROVIDE AN APPROVED BASE FOR MINI-SPLIT CONDENSOR
THERMOSTAT WIRE EXPOSED MUST BE PROTECTED
USE CONDUIT