Permit: T05CM02739

Parcel: 11306203A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/08/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/29/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. NEED REVISED APPROVED PLAN, INCORPORATING ALL REDLINE CHANGES FOR FINAL - HAVE EXISTING REDLINES AVAILABLE FOR COMPARISON
2. NEED TO SEE CLOSET FLANGE
3. REQUIRE APPROVED SITE UTILITY PLAN SHOWING SEWER AND WATER LOCATIONS
04/13/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
UNDERGROUND ABS INSTALLED PER REDLINES
OK TO COVER SUBJECT TO APPROVED PLAN REVISION
INSTALL FOAM PIPE WRAPS
04/12/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PIPE EXITING BUILDING HAS BACKPITCH AND IS EMBEDDED IN CONCRETE.
2. EXPOSE CAP ON UNUSED PIPING
3. FLAT AND BACK PITCH EXISTS IN SEVERAL LOCATIONS
4. CORRECT SLOPE, SUPPORT PIPING AT ELEVATOR W/REBAR TO PREVENT DAMAGE.
5. REMOVE CONCRETE
6. INCLUDE 1% SLOPE ON REDLINE AND ON REQUIRED PLAN REVISION
04/10/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEC. 412.2.1 REQUIRES FLOOR DRAINS.
PLAN REVIEW WAS 8/06
PROVIDE MIN. SLOPE IN ALL AREAS
PROVIDE REDLINES ON APPROVED PLAN FOR CHANGES MADE
PLAN REVISION REQUIRED AT LATER DATE
SUPPORT PIPING AT ELEVATOR SHAFT
UNCOVER PIPING COVERED W/DIRT