Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 04/29/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. NEED REVISED APPROVED PLAN, INCORPORATING ALL REDLINE CHANGES FOR FINAL - HAVE EXISTING REDLINES AVAILABLE FOR COMPARISON 2. NEED TO SEE CLOSET FLANGE 3. REQUIRE APPROVED SITE UTILITY PLAN SHOWING SEWER AND WATER LOCATIONS |
|
| 04/13/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* UNDERGROUND ABS INSTALLED PER REDLINES OK TO COVER SUBJECT TO APPROVED PLAN REVISION INSTALL FOAM PIPE WRAPS |
|
| 04/12/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PIPE EXITING BUILDING HAS BACKPITCH AND IS EMBEDDED IN CONCRETE. 2. EXPOSE CAP ON UNUSED PIPING 3. FLAT AND BACK PITCH EXISTS IN SEVERAL LOCATIONS 4. CORRECT SLOPE, SUPPORT PIPING AT ELEVATOR W/REBAR TO PREVENT DAMAGE. 5. REMOVE CONCRETE 6. INCLUDE 1% SLOPE ON REDLINE AND ON REQUIRED PLAN REVISION |
|
| 04/10/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEC. 412.2.1 REQUIRES FLOOR DRAINS. PLAN REVIEW WAS 8/06 PROVIDE MIN. SLOPE IN ALL AREAS PROVIDE REDLINES ON APPROVED PLAN FOR CHANGES MADE PLAN REVISION REQUIRED AT LATER DATE SUPPORT PIPING AT ELEVATOR SHAFT UNCOVER PIPING COVERED W/DIRT |