Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/17/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* UNIT 1 -- NEED GFI PROTECTION FOR WASHER OUTLET UNIT 2 -- GFI PROTECTION FOR WASHER CONNECTOR FOR HOOD EXTERIOR FRONT GFI NOT WORKING/MIS-WIRED EXTERIOR REAR OUTLET DEAD |
|
| 02/15/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) TIGHTEN ALL DEVICES SO THEY ARE NOT LOOSE 2) MASTER BATH LIGHT SWITCH IS UPSIDE DOWN 3) NEED OUTLET IN HALL WAY 4) HALL LIGHT NOT WORKING 5) INSTALL DISHWASHER AND DISPOSAL CORDS 6) GROUND HOOD AND INSTALL CONNECTOR FOR ROMEX 7) LIVING ROOM CKT IS DEAD-BURRIED HALL OUTLET ? 8) FRONT EXTERIOR GFI NOT WORKING, REAR GFI NOT WORKING 9) NEED GFI PROTECTION ON EXTERIOR WASHER OUTLET 10) NEED 120V SERVICE OUTLET FOR ROOF EQUIPMENT 11) PANEL DIRECTORY IS NOT CORRECTLY IDENTIFIED 12) PROVIDE IN USE OR W.P. COVER FOR DRYER OUTLET 13) GO THRU UNIT 2 TO CHECK FOR SAME VIOLATIONS |
|
| 01/19/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :*NEED TO PROPERLY INSTALL FLASHING |