Permit: T05CM02332

Parcel: 133243720


Addresses:

250 N PANTANO RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T05CM02332

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
03/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
COLUMN A/10 (14'4" - 16'10")
03/22/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CANCELLED BY CONTRACTOR
03/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
COLUMN @ LINES A/10 (10'4"-14'4")
03/20/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
COLUMN @ LINES A/10 (4'8"-10'4")
03/16/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/09/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH & CENTER TOWERS (21'8"-25')
03/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH TOWER (21'8"-25')
03/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 1/B-C.5 (12'-16'8"); CENTER TOWER (17'8"-21'8")
03/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH & SOUTH TOWERS (17'8" - 21'8"); COLUMNS, LINES A/2, A/2.5 (11'8"-14'8")
1. WALLS @ LINES 1/B-C CANNOT BE GROUT UNTIL ALL HORIZONTAL REINFORCEMENTS FOR ROOF LINE HAVE BEEN PLACED & REINSPECTED BY THE CITY.
03/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINES A/5.5-6, 5.5/A-B, 6/A-B (13'-8"-17' 8"); B/5.5-6 (DBL WALL) (15' 8"-19' 8")
02/28/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 1/B-C (10'-13'4"); B/3.5-5.5; B/8.5-10 (15'4"-20'); COLUMNS LINES A/1, A/2, A/2.5 (8'-11'8")
02/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINES B/3-6, G/8-10 (15' 4" -16' 8"); 3/A-B, 3.5/A-B, A/3-3.5 (14' 8" 17' 4")
02/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WALLS LINES A/8-8.5 (10'-15'4")
02/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WALL, LINES B/8.5-10 (10'-15'8"); COLUMNS, LINES A/1-A/2.5 (4'-8'), A/9, A/9.5 (10'8"-14'8")
02/17/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B/5.5-7 (10'-15'4")
02/16/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WALL @ LINES B/3-5.5 (10'-15'4"); COLUMNS @ LINES A/9-A/10, B/9, B/9.5 (8'4"-10')
02/15/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B/3.8-5.2 (10'-15'4"); COLUMNS @ LINES A/4, A/4.5, A/5 (15'8"-16'8")
02/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WALL @ LINE A/3-4 (10'-14'); COLUMNS @ LINES A/4, A/4-5, A/5, A/6-5, A/7, A/7-5 (10'-15'8")
02/09/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B/1-3 (10'-15'8"); COLUMNS @ LINES B/10 (3'4"-7'4")
02/08/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
02/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*PIERS @ LINES B/1-B/7.5,A/3-A/7.5 ( 8'-10') B/9.5, A/8-A/??5 ( 4'-8') B/8
02/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WALLS/PIERS @ LINES B/5-B/7.5 COLUMNS @ LINES A/1-A/7.5 (4'-8')
01/31/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 4/C.3-D, 7/C-3-D (12'-13'8"); 10/B-D (16'-19'4")
01/30/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*WALLS /PIERS @ LINES B/1-B/5
01/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINES D/1-10 (14'-17' 4"); 10/B-D (12'-16')
01/25/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*COLUMNS/PIERS @ LINES A/3,A/3.5, B/3,B/3.5, 1/B/3.5,1/B.3 ( 4'-8')
01/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINE D/1-10 (12'-14'); 1/C-D (8'-12')
01/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES4/C.3-D, 7/C.3-D (8'-12')
01/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B/1-10 (0-4'4"); 1/C-D, 4/C.3 - D (4'8'); D/1-7 (8'-12')
01/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES D/1-7 (4'-8')
01/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINES 10/B-10, D/7-10 (8'-12')
01/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINES D/7-10, 10/B-A (4'-8')
2) NEED DETAIL FOR GIRDER TO MASONRY WALL CONNECTION(S)-SHOWING ANY ADDITION VERTICAL AND OR HORIZONTAL REINFORCEMENT AS WELL
01/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CANOPY COLUMNS, LINES A/1-1/10 (0-4')
01/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 1/C-D, 4/C.3-D, 7/C.3-D, 10/B-D, D/1-10 (0-4')
12/30/2005 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) JOB SITE LOCKED-NO ACCESS
12/02/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*