Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM01852
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) OK ENGINEERS FIX OK |
|
08/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* NEED SHEAR TRANS FOR DETAIL OK TO LATH |
|
08/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED SHEAR CONNECTION (TRANSFER TO ROOF) CAN'T FIND ON PLAN, PER PENDICULAR AND PARALELL (CHECK PARALELL SITUATION FOR DRAG TRUSS, PERPENDICULAR FOR FRAMED BOXES 2) BLOCK ONE PIECE OF OSB TURNED WRONG WAY, BLOCK EDGE |