Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 03/16/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE INSPECTION |
|
| 03/15/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE INSPECTION |
|
| 03/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) ELEVATOR (17' 4"-21'-4") 2) INTERIOR COLUMNS N.W. OF ELEVATOR (13' 4"-17' 4") N.W. WALLS AT CENTER PORTION OF BLDG (24'-28') |
|
| 03/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N.W. & S.E. WALL OF SHELL #201 AROUND CENTER STAIR AREA (17'4"-21'4") EXTERIOR WALL/AREA @ SOUTH STAIRS (26'8"-30') |
|
| 02/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CENTER PORTION OF SHELL #201, WALLS N.E., N.W. & S.E. OF ELEVATOR (13'4" - 17'4") (2) EXTERIOR COLUMNS @ S-SIDE OF BUILDING (19'4"-22'4") |
|
| 02/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR COLUMNS (S.COLUMNS) @ EASTSIDE OF BUILDING (18'8"-23') - EXTERIOR COLUMNS @ SOUTHSIDE OF BUILDING (15'4"-19'4") |
|
| 02/15/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :*INCOMPLETE INSP | |
| 02/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2 COLUMNS @ EAST SIDE OF BUILDING, S. COLUMNS (10'8"-14'8"), N. COLUMNS (14'8"-18'8"); 2 COLUMNS @ SOUTHSIDE OF BUILDING (10'8"-15'4") |
|
| 02/10/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR GROUTING ON 2/13/06 INCOMPLETE INSPECTION |
|
| 02/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LINES 2.3/C.?-E, E-7/23-23.3 (12'-14' 8") |
|
| 02/02/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*COLUMN @ N.W SIDE OF LOBBY ( 13'4" -18') | |
| 01/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) ELEVATOR (8'-13' 4"); COLUMNS NORTH OF ELEVATOR (8'-12') |
|
| 01/30/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/27/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) S. W. WALL OF ROOM #102 AND CENTER STAIRS (8'-13' 4"); ELEVATOR AND 2 COLUMNS AT S.E. SIDE OF ROOF #100 (4'-8'); LINE 11/S-T (9'-4"-13' 4") |
|
| 01/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EXTERIOR WALL AT S.E. SIDE OF BLDG (12' 8"-14') |
|
| 01/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* S.W. WALLS OF ROOM #102 & CENTER STAIRS (4'8"-8'8"); ELEVATOR (0-4'); N.W. COLUMNS/WALLS OF LOBBY #100 (8'8"-12'); EXTERIOR COLUMNS/WALLS @ S.E. SIDE OF BUILDING 8'8"-12'8" |
|
| 01/19/2006 | REINFORCED MASONRY PRE-GROUT | Cancelled | CANCELLED PER LAURA OF VENTURE WEST, LAURA GAVE SHERRIE AS THE PERSON TO CONTACT #465-6749 | |
| 01/19/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/17/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/13/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 15.5/H-L, 11/Q.S-5, 1-2/V-W, W/2-3.5 & SOUTH & STAIR AREA (8'8"-15'14") COLUMNS @ NW SIDE OF LOBBY AND EXTERIOR COLUMNS SOUTHEAST OF LOBBY @ LINES 11-15.5/M-Q.5 (4'8"-8'8"); WALL @ LINES Q.5/8-11 (4'8"-8'8"); SW WALL OF CENTER STAIRS & ELEVATOR (0-4'8") |
|
| 01/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) L-Q.5/11-15.5 (8'-13'4"); 15.5/H-L (4'-8') |
|
| 01/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LINES 1/Q-V (8'8"-13'4"), N.W. EXTERIOR COLUMNS-4 CENTER COLUMNS (0-4'8") AND 4 EXTERIOR (0-2'8") 2) CONTRACTOR TO HOLD GROUT DOWN IN ORDER TO MAINTAIN PROPER LAP SPLICES |
|
| 01/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*WALLS/COLUMNS @ LINES 1/Q-V,2/W,11/Q-11/R ( 4'8"-8'8") COLUMNS@ LOBBY ( 0-4'8")N. WALL OF ROOM # 104 ( 8'8"-13'4) SPECIAL INSPECTOR TO VERIFY THAT GROUT IS HELD DOWN IN ORDER TO MAINTAIN PROPER LAP SPLICES | |
| 12/29/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 1-5/K.5-N, 10.5-13/A-D, 1/N-Q (11' 4" - 13' 4") WALLS/COLUMNS @ LINES 11/S-V & SOUTH STAIRS (4'8" - 8'8") |
|
| 12/22/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) COLUMNS/WALLS AT LINES 1/Q-W, 11/Q-V AND SOUTH STAIR AREA (0-4'8") 2) CONTRACTOR WILL HOLD GROUT DOWN IN ORDER TO MOUNTAIN PROPER ? SPLICES |
|
| 12/20/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*LINES 10.5-13/B-D,13/A-B (4'8"-11'4") 23/B-C.5,C.5/21.5-23,22/E-L (8'8"-13'4") | |
| 12/15/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LINES L-Q/11-15.5, K-M.3/1-4, 1/M.3-Q (4'8"-9'4"); Q/8-11 (0-4'8") |
|
| 12/13/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LINES A/13-15.? (4'8"-8'8"); A/15.5-23, L/15.5-22 (8'-13'4"); COLUMNS AT LINES 23/C AND 23/F (4'8"-9'4") |
|
| 12/08/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) S.E. WALL OF SHELL #103 (0-48") 2) WEST WALL/COLUMN OF SOUTH HALF OF SHELL #103 (OUTSIDE FACE OF POP OUT, 0-4') |
|
| 12/06/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*N.W WALL OF SHELL # 103 EACH SIDE OF LOBBY, W. WALL OF SHELL # 103, LINES 1/M.3-P-5 ( 0-4'8") | |
| 12/02/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*EAST HALF OF SHELL # 103 NORTH WALL/COLUMNS ( 4'8"-8'8") WALLS @ STAIR AREA ( 4'8"-8'-8") | |
| 11/30/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*EAST HALF OF SHELL # 103, N. WALL /COLUMNS ( 4'8" -8'8") S .WALL , LINES A/13-15.5 ( 0-4'8") | |
| 11/23/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*EAST HALF OF SHELL # 103 ( 0-4'8") | |
| 11/22/2005 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :*CONTRACTOR CANCELLED | |
| 09/07/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM WALL AT PERIMETER OK PER RFI |
|
| 09/01/2005 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) YOU MAY NOT TRIPPLE SPLICE REINFORCEMENT IN MASONRY. YOU WILL NEED TO EXTEND YEAR ADDED BARS MINIMUM 32" PAST TOP OF FOOTING DOWELS |