Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2005 | ROOF NAILING | Approved | IVRS - Inspection :*APPROVED | |
| 11/09/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS TO ROOF, CONTRACTOR NOT ON SITE AND DOOR LOCKED |
|
| 11/03/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*SEE NOTE (1) NEED MORE BLOCK TO GET TO 10' FROM EXTERIOR WALL & 4" O.C NAILING TO EXTENTS SHOWN ON PLANS |
|
| 10/25/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*LEDGER NAIL TO SHEAR BLOCK PER DETAIL 202 INSUFFICIENT NAILING TOP OF CRICKET DETAIL 204 INCORRECT ATTACHEMENT TO WOOD BLOCK TO ROOF ( # 10 X 3 1/2" SCREWS ASKED FOR ) PLAN CALL FOR 16D NAILS AT CONNECTIONS YOU USED 12D SEE KEYNOTE 6 PP 53.0 |