Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM00974

Parcel: 136321070


Addresses:

4590 S LAREDO CT

Inspection Status: Partial Approval

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/28/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BLOCK UNDER JOINT ROOF DECK, AT GLU LAM 45 DEGREE ANGLE AND NAIL ENDS
2) IS SLOPE 1/4" PER FT. ?
3) HANGER AT 45 DEGREE GLU LAM IS UNDER SIZE ASK PLAN INSPECTOR TO CALC LOAD
4) 2 X 6 RAFTERS AT JOINT TO 45 DEGREE GLU LAM OVER 6'-0" LONG NEED SCKEWED RAFTER HANGER REQUIRED
5) MAKE SURE ROOF DECKING IS NAILED TO LEDGER AT 6" ON CENTER
6) NOTE 2" DRAIN FOR WASHER IS TO BE SLOPED AT 1/4" PER FT.