Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/28/2007 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 02/16/2007 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 6" CONCRETE SLAB ON GRADE OVER EXT. RETAINING WALL ON NORTH SIDE OF BUILDING 78' L WITH #4 @ 12" O.C EA WAY CONNECTED TO DOWELS ON BOTH SIDES OF WIDTH. DETAIL A ON SHEET ADD -1 |
|
| 02/09/2007 | BUILDING PRE-SLAB | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLANS DON'T SHOW DETAIL AND SPECIFICATION FOR SLAB CONNECTED WITH RETAINING WALL, PROVIDE RFI APPROVED BY ENGINEER AND DSD CITY OF TUCSON, PLUS SPECIAL INSPECTION REPORT FOR EPOXY CONNECTIONS, FOR COPPER PIPES ON SLAB. |