Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM00653

Parcel: 129043570


Addresses:

540 S NORRIS AV

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/26/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
12/23/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*PLEASE LEAVE A NAME AND CONTACT NUMBER WHEN SCHEDULING THIS INSPECTION.
NO ADDRESS POSTED
NO PERMITS POSTED
PLANS NOT IDENTIFIED BY ACTIVITY NUMBER
N/C CAST IRON WITH HUSKEE BANDS, AS HIGHLIGHTED ON PLAN OK TO COVER-WATER TEST ONE RISER TO TEN FEET.
09/20/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
2" DRAIN FOR ALT #1 WASH BASIN AND ELECTRIC WATER COOLER OK
L-3H AND EWC AT WEST WALL IS DELEATED